09/19 1200 Series Electric Water Coolers
Page 8 of 21
H. GENERAL OPERATION
H.1. USING THE BUBBLER
•
Press the push-button or place hand in front of sensor (on sensor equipped models) on the front
of the water cooler to activate the bubbler flow.
H.2. USING THE BOTTLE FILLER
•
Insert a bottle below the nozzle to activate the water flow.
•
Remove the bottle from below the nozzle to stop the water flow.
H.3. FILTER LIFE (Filtered units only)
•
The filter is designed to last for a maximum of 1 year or 3,000 gallons, whichever comes first.
•
In order to ensure dispensed water quality, the unit will automatically disable water flow when the
filter reaches 3,000 gallons. Water flow will be re-enabled after the filter is replaced.
H.4. SMART ENERGY SAVING (Filtered and/or Bottle Filler units)
•
The filtered and/or bottle filler units are set to Smart Energy Saving as the factory default. These
units will automatically save energy by turning off the chiller during dark ambient light conditions
when there has been no recent use of the unit.
I. NOTIFICATIONS
I.1. WATER COOLER INDICATION LIGHTS (ALL MODELS EXCEPT 1201S AND 1202S)
•
Power
= Red LED
o
Solid ON
– when power is applied
•
Filter
= Blue LED (Filtered units only)
o
Solid ON
– Filter life 100% to 11% remaining
o
Intermittent Flash (once/3 second)
– Filter life 10% to 0% remaining
o
Rapid Flash (once/second)
– Filter life expired
•
Energy Saving
= Green LED
o
OFF
– Energy Saving Mode disabled
o
Solid ON
– Energy Saving Mode enabled
o
Intermittent Flash (once/3 second)
– Bubbler is deactivated due to stuck button or
sensor issue. Clean sensor lens and cycle power to unit.
o
Rapid Flash (once/second)
– Actively saving energy (compressor and fan disabled)
I.2. BOTTLE FILLER INDICATION (MODELS WITH BOTTLE FILLER ONLY)
•
Bottles Saved:
Indicates approximately 1 bottle saved for each 17oz dispensed from the water
cooler, whether it be from a bubbler or the bottle filler.
•
Filtering Icon (Filtered units only):
o
Solid ON at all times - 100%-11% filter capacity remaining
o
Pulsing when not activated - 10%-1% filter capacity remaining
o
OFF - 0% filter capacity remaining (filter expired)
•
Energy Efficiency Icon
o
Solid ON = Basic or Programmable Energy Saving Mode enabled
o
Intermittent Flash = Unit actively saving energy (compressor and fan disabled)
o