background image

             

8 3/4"

222mm

 FROM HANGER 

BRACKET HOLES

PAGE 19 OF 21

RETROFIT INSTALLATION

DETAILS

NOTES:

THE 12XX COOLER SERIES IS ABLE TO RETROFIT IN PLACE OF A NUMBER OF COMPETITOR MODELS.  SEE

       RETROFIT TABLE ABOVE FOR PARTIAL LIST OF COOLERS ABLE TO BE REPLACED BY THIS ONE.  
       

THE FOLLOWING DISCLAIMERS APPLY:

THE 12XX COOLER CENTERLINE MAY NOT MATCH THE OLD COOLER'S CENTERLINE, SINCE THE 12XX 

COOLER DRAIN MUST BE 2 5/8" OFF OF CENTER.  THIS MAY AFFECT ADA COMPLIANCE.
FOR HI-LO COOLER RETROFITS, EXISTING RIGHT-SIDE COOLER MUST BE THE LOW COOLER.  DRAIN, 

WATER, AND ELECTRIC SERVICES MUST BE POSITIONED BEHIND RIGHT-SIDE UNIT.
THERE MUST BE WALL BLOCKING OR OTHER STRUCTURAL MATERIAL BEHIND HAWS MOUNTING HOLES.

VERIFY THAT DRAIN, ELECTRIC, & WATER SERVICES ARE LOCATED WITHIN BOUNDARIES SPECIFIED ON 

THIS SHEET AND THE NEXT.  SOME RETROFITS MAY REQUIRE THE ELECTRIC OUTLET TO BE MOVED.

THE P-TRAP IS NOT SUPPLIED.  THE VERTICAL DIMENSIONS GIVEN ARE BASED UPON INSTALLATION USING

       OF A KEENEY 200W P-TRAP, AND SHOULD THEREFORE BE REGARDED AS REFERENCE-ONLY.  

THE CENTERLINE OF THE DRAIN STUB-OUT MUST BE BETWEEN 3" [76mm] & 4-5/8" [118mm] OR BETWEEN 6"

       [152mm] & 8-3/4" [229mm] BELOW THE LOWERMOST EWC MOUNTING BRACKET HOLES IN ORDER FOR THE 
       P-TRAP TO AFFIX PROPERLY TO THE DRAIN TAILPIECE.  
        - DEPENDING ON STUB-OUT HEIGHT, SOME TRIMMING OF THE TAILPIECE WILL BE REQUIRED. 
        - MOUNTING THE STUB-OUT IN THE HIGHER RANGE WILL REQUIRE TRIMMING THE TAILPIECE ABOVE THE 
          LOWER DRAIN HOSE BRANCH.  

IN THIS INSTANCE, THEREFORE, A HI-LO COOLER CANNOT BE

          INSTALLED.

WHATEVER P-TRAP AND STUB-OUT PLUMBING ARE USED, CARE SHOULD BE TAKEN TO ENSURE THAT THE 

       P-TRAP CAN SEAL TO THE STUB-OUT PROPERLY AND STILL ALIGN TO  THE DRAIN TAILPIECE (LOCATED AT
       THE GIVEN DIMENSIONS).

3

4

5

6

HIGHEST & LOWEST

P-TRAP HEIGHTS

5

LOW COOLER BRACKET HEIGHT

ADULT STANDING

ADULT ADA

CHILD ADA

33 7/8"

28 3/8"

25 3/8"

RETROFIT TABLE

MANUFACTURER

MODEL

HAWS

ALL MODELS STARTING WITH 

HWUACP

ELKAY/HALSEY 

TAYLOR

- ALL MODELS STARTING WITH EB, 

EI, EMA, EN, EZ, HAC HVR, LI, LMA, 

LZ, TB, & TI 

- SINGLE COOLER MODELS 

STARTING WITH VRC & LVR 

OASIS

ALL VERSACOOLER II MODELS

SUNROC

ALL MODELS STARTING WITH ADA

MURDOCK 

A171, A171.8, & A172.8UBL MODELS

NOTE:  THE WATER STOP VALVE 

MUST BE RELOCATED TO RETROFIT 

A FILTERED 12XX COOLER

3

PAGE 19 OF 21

DRAIN STUB-OUT/P-TRAP DETAIL

(VIEWED FROM TOP)

DRAIN
STUB-OUT
(NOT SUPPLIED)

1-1/4" P-TRAP
(NOT SUPPLIED)

WALL

FACE

6

   2 7/8"

73mm

  

   6 5/16"

161mm

  

2 3/8"

61mm

MAX

CAN'T USE WITH 
HI-LO MODELS.

3" [76mm] 
FROM HANGER 
BRACKET HOLES

© 2020 Haws Corporation - All Rights Reserved.  HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.

 

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT
IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.

APPROVED:

DRAWN:

PART NUMBER

SCALE:

REVISION

JL

07/25/18

5

1:8

TM

09/29/20

DRAWING TYPE:

SIZE:   A

 5343

BY:

DHP

INSTALLATION

DATE:

DATE:

REV. ECN:

5595

CHK'D.:

MODEL(S)

1455 KLEPPE LANE

SPARKS, NEVADA  89431

(775) 359-4712  FAX (775) 359-7424

E-MAIL:  [email protected]
WEBSITE: WWW.HAWSCO.COM

DHP

ECN:

SHEET 5 OF 7

0510000866.D

12XX ELECTRIC WATER COOLERS

5

FLOOR LINE

MOUNTING BRACKET

HAWS COOLER

NOTE LOCATING

NOTCH FOR

DRAIN STUB-OUT

CENTERLINE

PERMISSIBLE LOCATIONS FOR DRAIN STUB-OUT

  

3"

76mm

  

   4 5/8"

117mm

  

  

6"

152mm

  

   8 3/4"

222mm

  

BRACKET

HEIGHT

(SEE TABLE

ABOVE)

  2 5/8"±1/4"

67mm±6

  

Summary of Contents for 1201S

Page 1: ...l power to outlet before installing or servicing NOTICE A The electrical receptacle must have code approved ground fault circuit interrupter GFCI protection for personnel B Care should be taken not to damage refrigeration system lines or electrical wires during installation C Installation must conform to all applicable codes and standards NOTE TO INSTALLER Please leave this information with the Ma...

Page 2: ...e for corrosive environments such as enclosed chlorinated pool areas or very dusty areas The ambient air temperature must be maintained between 40 F and 104 F at all times Installation into a location not meeting these limitations will void the warranty SUPPLY LINE The min recommended size is 1 2 IPS with 30 90 psig 2 6 ATM flowing pressure Where sediment or mineral content is a problem an upstrea...

Page 3: ...ght Put a line on the nut using a marker Tighten exactly one additional full 360 degrees turn with a wrench using the line to count turns 9 Install the P trap If necessary trim the water cooler s drain tailpiece in place so it interfaces properly with the P trap inlet Pliers may be required to tighten the nuts to a leak tight condition 10 If the unit has a filter install the filter now Take care n...

Page 4: ...ew from its hole in the left unit and use it to secure the green ground wire to that same location 35 Snap wires into the plastic wire clip near the ground screw to keep them away from the sheet metal edges D START UP 36 Open the water supply valve and check the system for leaks 37 Plug the power cord into the wall receptacle which should presently be powered off at the breaker panel Check that al...

Page 5: ... returns to main menu Cancel returns to main menu without changing program Sets 12 hour clock AM or PM and advanced to programming OFF time see Note 1 Cancel returns to main menu with changing program Off 1 to 12 sets hour to turn Off energy saving and advance to A or P field see Note 1 Cancel returns to main menu without changing program Sets 12 hour clock AM or PM and advanced to OFF setting see...

Page 6: ...er cord 6 Remove the black plastic cover underneath the bowl by removing the 4 screws using either a phillips bit or 5 16 nut driver 7 Remove the 3 T20 head screws attaching the bubbler to the bowl then pull up on the bubbler to release the push to connect fitting from it 8 Store the bubbler and T20 head screws in a safe location so that they can be reinstalled later 9 Install the cover plate by u...

Page 7: ...steps 1 Remove the 4 screws holding the skirt to the bottom of the frame Then remove the skirt by sliding the skirt away from the cooler a NOTE For dual units the filter is in the right side unit 2 Place a towel or bucket below the cooler to collect the small amount of water that may drip from the filter head or filter during the next steps 3 Optional Turn the water supply valve to the off positio...

Page 8: ...ATIONS I 1 WATER COOLER INDICATION LIGHTS ALL MODELS EXCEPT 1201S AND 1202S Power Red LED o Solid ON when power is applied Filter Blue LED Filtered units only o Solid ON Filter life 100 to 11 remaining o Intermittent Flash once 3 second Filter life 10 to 0 remaining o Rapid Flash once second Filter life expired Energy Saving Green LED o OFF Energy Saving Mode disabled o Solid ON Energy Saving Mode...

Page 9: ...whether the solenoid valve is working 3 Low water flow from bubbler a b c d e Replace filter Verify minimum 30 psig supply pressure Verify supply valve is in full open position Unscrew nozzle and flush with clean water Replace nozzle 4 Low water flow from bottle filler a b c d e Replace filter Verify minimum 30 psig supply pressure Verify supply valve is in full open position Unscrew aerator and f...

Page 10: ...e unit and ensure fan runs initially for approximately 10 seconds Clean condenser fins of dust and debris Verify inlet water and ambient temperatures are below specification maximum 2 E012 SENOB Bottle filler sensor is obstructed a b c Clear error in programming mode and power cycle unit and check error to validate Remove obstruction from aperture Clean aperture with soft cloth that won t scratch ...

Page 11: ...ance Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation K 2 2 Declaration de Conformité Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appare...

Page 12: ...so includes costs of outbound freight but not express freight of the part or parts from the factory repair department but only if the part or parts and the purported defect or defects are covered by this LimitedWarranty in Haws sole discretion When the product is located outside the United States and Canada Haws obligation under this Limited Warranty includes only providing a replacement for any p...

Page 13: ...C111 HC111 HC111 14 FAN MOTOR HC117 HC117 HC117 HC117 HC117 HC117 HC117 HC117 15 THERMOSTAT 5810 5810 5810 5810 5810 5810 5810 5810 16 COMPRESSOR THERMAL PROTECT HC115 HC115 HC115 HC115 HC115 HC115 HC115 HC115 17 COMPRESSOR START RELAY HC116 HC116 HC116 HC116 HC116 HC116 HC116 HC116 18 BOTTLE FILLER DRAIN BASIN 0410000286 0410000286 0410000286 0410000286 19 BOTTLE FILLER ASSEMBLY 1930 1930 1930 19...

Page 14: ... WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 5 12XX ELECTRIC WATER COOLERS 1 8 TM 09 29 20 DRAWING TYPE SIZE A 5343 BY DHP PARTS BREAKDOWN DATE DATE REV ECN 5595 CHK D MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM DHP ECN WHEN ORDERING PARTS PLEASE SPECIFY PART NUMBER SHEET 2 OF 2 0510000866 2020 Ha...

Page 15: ...HIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 5 1 12 TM 09 29 20 DRAWING TYPE SIZE A 5343 BY DHP INSTALLATION DATE DATE REV ECN 5595 CHK D DHP WEBSITE WWW HAWSCO COM MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359...

Page 16: ...3 4 349mm 2020 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 5 1 12 TM 09 29 20 DRAWING TYPE SIZE A ...

Page 17: ...tion THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE APPROVED DRAWN PART NUMBER SCALE REVISION JL 07 25 18 5 1 12 TM 09 29 20 DRAWING TYPE SIZE A 5343 BY DHP INSTALLATION DATE DATE REV ECN 5595 CHK D MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAW...

Page 18: ...BING SUPPLIED HIGH EWC TUBING CONNECTION ON LOW COOLER ROUTE TUBING THROUGH CIRCULAR HOLE IN SHEET METAL 3 8 ELBOW FIELD CONNECTION 2020 Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJ...

Page 19: ... CARE SHOULD BE TAKEN TO ENSURE THAT THE P TRAP CAN SEAL TO THE STUB OUT PROPERLY AND STILL ALIGN TO THE DRAIN TAILPIECE LOCATED AT THE GIVEN DIMENSIONS 3 4 5 6 HIGHEST LOWEST P TRAP HEIGHTS 5 LOW COOLER BRACKET HEIGHT ADULT STANDING ADULT ADA CHILD ADA 33 7 8 28 3 8 25 3 8 RETROFIT TABLE MANUFACTURER MODEL HAWS ALL MODELS STARTING WITH HWUACP ELKAY HALSEY TAYLOR ALL MODELS STARTING WITH EB EI EMA...

Page 20: ...OFIT INSTALLATION DETAILS PAGE 20 OF 21 A WALL RECEPTACLE WITH A STANDARD SIZE WALL PLATE SHOULD BE LOCATED WITHIN THIS AREA HAWS COOLER MOUNTING BRACKET PERMISSIBLE ELECTRICAL RECEPTACLE LOCATIONS 1 26mm 6 1 4 159mm 3 77mm 10 5 8 271mm 14 356mm 13 1 8 334mm 6 152mm 4 1 8 105mm 5 7 8 149mm 5 127mm 2X 1 7 8 48mm HAWS COOLER MOUNTING BRACKET PERMISSIBLE WATER SUPPLY LOCATIONS WATER SUPPLY VALVE IS P...

Page 21: ...RAWN PART NUMBER SCALE REVISION JL 07 25 18 5 1 8 TM 09 29 20 DRAWING TYPE SIZE A 5343 BY DHP INSTALLATION DATE DATE REV ECN 5595 CHK D MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM DHP ECN SHEET 7 OF 7 0510000866 D 12XX ELECTRIC WATER COOLERS NOTE THE LEFT EDGE OF THE LABEL FACING OUT THE SIDE DURING INSERTION OF FILTER IN...

Reviews: