Hawker MasterLine puls/EU Installation And Operation Manual Download Page 11

 

 

GB

 

 3 

v014r0 

 

 
Information display status indication and progress of charging 

 

 

Charging start-up: 
A new battery has been connected and charging has not started yet. 

 

Battery is being charged 

 

Battery is charged 80% 

 

Battery is charged 100% 

 

A new battery has been connected and charging could not be started yet  
because of a mains error. 

 

Error code 

Several safety monitoring functions ensure the protection of battery and battery charger. 

 

If charging was stopped or interrupted because of battery errors, the

 battery error LED (8) is illuminated. 

 

Indication

 

Description of error

 

Remedy

 

F0 

U < 2,0 V/Z 

Battery voltage below 2.0 V/cell after 1 hour 

Have battery checked 

F3 

U < 1,5 V/Z 

Battery voltage below 1.5 V/cell when connected. 
Charger waits for increase in battery voltage, the 
charging process starts automatically. 

Battery is discharged too deeply. 
Call a service technician 

F4 

U > 2,4 V/Z 

Battery voltage over 2.4 V/cell when connected. 
Charger waits for increase in battery voltage, the 
charging process starts automatically. 

Battery is fully charged. 
 

F7 

U < 2,48V/Z 

Safety time was exceeded. 

Have battery checked or matching 
of charger to battery is incorrect 

 

If charging was stopped or interrupted because of charger errors, the

 charger error LED (5) is illuminated. 

 

Indication

 

Description of error

 

Remedy

 

E2 

Charger data 

The charger settings are incorrect. 

Reset the charger data or call your service 

E3 

Service 

The parameters of the charger are incorrect. 

The charger is defective. Call your service. 

E5 

Service 

The parameter data of the charger are incorrect. 

The charger is defective. Call your service. 

E6 

Test error 

The charger test was stopped because of an error. 

Repeat the test and call your service, if necessary 

E11 

I > 0 A 

The charging current was 4% over the charger's rated 
current when the power switch was off. 

The charger is defective. Call your service. 

E12 

EUW 

Pressure error of electrolyte circulation pump 

Check air adapter in charging plug, 
check hoses on battery 

E13 

I > 125% 

The charging current was 125% over the charger's 
rated current when the power switch was on. 

Call a qualified electrician.  
Check the mains power setting at the transformer. 

E20 

U < 1 V/Z 

The cell voltage of the battery is less than 1 V/cell. 

Have battery checked or matching 
of charger to battery is incorrect 

E21 

Mains error 

No mains voltage or the transformer is overheated. 

Check the mains power plug and mains fuse. 
Call a qualified electrician 

E30 

I < 2% 

The charging current was 2% under the charger's rated 
current when power switch was on. 

Check if the charger is matched to the battery. 
Call a qualified electrician 
Check the mains power setting at the transformer. 

 

Maintenance 

Always observe local regulations when doing maintenance on the charger. 
No special maintenance is required for the charger. 
Checking and possibly cleaning the charger, depending on the dirt / dust of the environment at the site of use, is required at suitable intervals. 

 

 

z

  The voltages inside the charger are potentially lethal. 

 

Only qualified electricians are allowed to open and repair the charger.  

z

  Disconnect charger from mains supply and battery before opening! 

 

 

Summary of Contents for MasterLine puls/EU

Page 1: ...traktionsbatterier Installations och bruksanvisning 16 S Ladeapparat for traksjonsbatterier Installasjons og bruksanvisning 19 N Trukkiakkuvaraaja Installations og brugervejledning 22 DK Lader til tra...

Page 2: ...ea Sie ov pr d omre na napetost ebeke gerilimi Vorsicherung gL Automat D Mains fuse gL ti D Fusible gL Disjoncteur D voorzekering gl automatisch D sulake kelt automaatti D f rs kring gl automat D fors...

Page 3: ...PE N L1 1 A1 2 4 3 X1 EC2 A 8 2 7 2 1 2 3 4 3 1 5 6 X3 X2 12 1 W0 L1 K1 K2 3 4 5 Wp nc 9 0 D B C A E F 2 1 6 X4 4 3 5 TENSION SECTEUR NET AANSLUITING MAINS VOL T AGE 1 N PE AC 50Hz 230V NETZSP ANNUNG...

Page 4: ...B S 50260 EU E2 1 N PE AC 230V 50Hz S 50262 EU E3 E4 3 PE AC 400V 50Hz...

Page 5: ...251 280 281 320 48 40 3 2 13 9 16 53 281 320 321 350 251 280 281 320 321 375 48 45 3 4 5 0 10 68 321 350 351 420 281 320 321 375 376 430 48 50 D 400 V 3 6 5 2 10 G 3 1 70 351 420 421 490 321 375 376 4...

Page 6: ...zanschluss Der Anschluss erfolgt ber das Netzkabel mit dem Netzstecker z Das Ladeger t darf nur von einer Elektrofachkraft ge ffnet werden z W hlen Sie die Vorsicherung entsprechend den Technischen An...

Page 7: ...Die Ladeerhaltungsfunktion kompensiert den Eigenverlust der Batterie Die Ausgleichsladung sorgt f r einen Ausgleich der Leistungsunterschiede innerhalb der Batteriezellen Ladungsunterbrechung Batteri...

Page 8: ...undendienst rufen E3 Service Die Parametrierdaten des Ladeger tes sind fehlerhaft Das Ger t ist defekt Kundendienst rufen E5 Service Die Parametrierdaten des Ladeger tes sind fehlerhaft Das Ger t ist...

Page 9: ...wall mounting holes see page A Mains connection The charger is connected to the mains with the plug on the power cable z The charger may only be opened by a competent electrician z Select the main fu...

Page 10: ...charging The trickle charging function compensates any self losses of the battery The equalizing charge equalizes any differences in power within the battery cells Interruption of the charging process...

Page 11: ...s defective Call your service E5 Service The parameter data of the charger are incorrect The charger is defective Call your service E6 Test error The charger test was stopped because of an error Repea...

Page 12: ...e cordon lectrique avec la prise secteur z Seul un lectricien qualifi est autoris ouvrir le chargeur z Choisir le fusible secteur en fonction des Informations techniques page A z Il est possible d ada...

Page 13: ...ge de maintien et en charge d galisation La fonction charge de maintien compense la perte intrins que de la batterie La charge d galisation sert quilibrer la diff rence de puissance entre les l ments...

Page 14: ...es de param trage du chargeur sont erron es L appareil est d fectueux Appeler le service apr s vente E6 D faut de contr le Le contr le du chargeur a t interrompu suite une erreur R p ter le contr le...

Page 15: ...de voedingskabel met netstekker z De lader mag alleen door een elektrische vakman geopend worden z Let op de juiste smeltveiligheid in de verdeelkast zie Technische Informatie pagina A z De lader kan...

Page 16: ...voor het behoud van de lading compenseert de zelfontlading van de batterij De vereffeningslading zorgt voor een compensatie van de ladingsverschillen van de batterijcellen onder zich Onderbreking van...

Page 17: ...de lader zijn verkeerd De lader is defect Servicepersoneel contacteren E5 Service De parametergegevens van de lader zijn verkeerd De lader is defect Servicepersoneel contacteren E6 Teststoring De zel...

Page 18: ...so sivu A Verkkoliit nt Verkkojohto on varustettu pistotulpalla z Varaajan saa avata vain s hk alan ammattilainen z Valitse etusulake teknisten tietojen mukaisesti katso sivu A z S hk alan ammattilain...

Page 19: ...nen yll pitovaraus ja varauksen tasaus Yll pitovaraus kompensoi akun itsepurkautumisen Varauksen tasaus tasaa akkukennojen sis iset tehoerot Varauksen keskeytys Kytke akku irti R j hdysvaara z l koska...

Page 20: ...yhteys huoltoon E5 Huolto Varaajan parametrien arvot virheelliset Laite on viallinen Ota yhteys huoltoon E6 Testausvika Laitetesti on ep onnistunut tai keskeytynyt vian vuoksi Suorita testi uudelleen...

Page 21: ...ing Laddaren ansluts ver n tkabeln med n tkontakten z Laddaren f r endast ppnas av en beh rig elektriker z V lj s kring utg ende fr n de tekniska uppgifter p sidan A z Avvikande n tsp nning kan av beh...

Page 22: ...ddning och utj mningsladdning Funktionen underh llsladdning kompenserar batteriets egen kapacitetsf rlust Utj mningsladdningen ser till att effektskillnader mellan battericellerna j mnas ut F r att av...

Page 23: ...darens parameterdata r felaktiga Laddaren r defekt Kontakta kundtj nst E5 underh ll Laddarens parameterdata r felaktiga Laddaren r defekt Kontakta kundtj nst E6 Testfel Testen av laddaren har avbrutit...

Page 24: ...n og stikkontakt z Ladeapparatet skal kun pnes av en elektriker z Velg nettsikring i henhold til Tekniske opplysninger p side A z Ved avvik fra nettspenningen kan apparatet tilpasses Dette m bare utf...

Page 25: ...lading Vedlikeholdsladingsfunksjonen kompenserer for eget tap i batteriet Utjevningsladingen s rger for en utjevning av effektforskjeller mellom battericellene Avbryte oppladingen Frakoble batteriet E...

Page 26: ...ce E3 Service Ladeapparatets parameterdata er feil Apparatet er defekt Tilkall kundeservice E5 Service Ladeapparatets parameterdata er feil Apparatet er defekt Tilkall kundeservice E6 Testfeil Apparat...

Page 27: ...inet side A Nettilslutning z Laderen m kun bens af en elektriker z V lg forsikringen svarende til Tekniske oplysninger se side A z Afvigelser af netsp ndingen kan i apparatet tilpasses af en fagl rt e...

Page 28: ...udligningsladning Funktionerne til opretholdelse af ladningen kompenserer for batteriets eget tab Udligningsladningen s rger for en udligning af effektforskellene i battericellerne Afbrydelse af ladep...

Page 29: ...aderens parameterdata indeholder fejl Apparatet er defekt Kontakt kundeservice E5 Service Laderens parameterdata indeholder fejl Apparatet er defekt Kontakt kundeservice E6 Testfejl Apparatetest afbru...

Page 30: ...ect a a trav s del cable de red con el conector de red z El cargador de bater a solamente lo debe abrir personal especializado en electrot cnia z Escoger el fusible de red en funci n de las informacio...

Page 31: ...ci n La funci n de mantenci n de carga compensa la p rdida propia de la bater a La carga de compensaci n se encarga de una compensaci n de las diferencias de potencia dentro de los elementos de la bat...

Page 32: ...o Llamar al servicio de cliente E5 Servicio Los datos de parametrizaci n del dispositivo de carga est n defectuosos El dispositivo est defectuoso Llamar al servicio de cliente E6 Fallo de prueba la pr...

Page 33: ...oldalakon H l zati csatlakoz s A csatlakoz s h l zati k belen kereszt l a h l zati csatlakoz dug val t rt nik z A t lt k sz l ket csak villanyszerel szakember nyithatja ki z V lasszuk ki az el t t bi...

Page 34: ...A t lt s befejez se ut n tmegy automatikus t lt sfenntart sra s kiegyenl t t lt sre A t lt sfenntart funkci kompenz lja az akkumul tor saj t vesztes g t A kiegyenl t t lt s gondoskodik a teljes tm ny...

Page 35: ...rezett adatai hib sak A k sz l k hib s E5 Szerviz A t lt k sz l k param terezett adatai hib sak A k sz l k hib s E6 Teszthiba A k sz l kteszt egy hiba miatt megszakadt Ism telje meg a tesztet adott es...

Page 36: ...cuj cych do monta u ciennego zob Obudowa str A Przy cze sieciowe Pod czenie nast puje poprzez kabel sieciowy z wtyczk sieciow z Tylko elektryk mo e otwiera prostownik z Dobra bezpiecznik wst pny zgodn...

Page 37: ...nia adowania kompensuje straty w asne baterii adowanie wyr wnawcze zapewnia wyr wnanie r nic mocy w obr bie ogniw baterii Przerwanie adowania od czy bateri Niebezpiecze stwo wybuchu z Wtyczki prostown...

Page 38: ...metryzacji prostownika s b dne Urz dzenie jest uszkodzone Wezwa serwis E5 Serwis Dane parametryzacji prostownika s b dne Urz dzenie jest uszkodzone Wezwa serwis E6 B d testowy Test urz dzenia przerwan...

Page 39: ...viz str nka A S ov p pojka Nab je ka se p ipojuje s ov m kabelem k s ov z str ce z Nab je ku sm otv rat pouze elektrik z Zvolte p edb n ji t n podle Technick ch daj viz str nka A z Odchylky s ov ho na...

Page 40: ...vac a vyrovn vac nab jen Funkce udr ovac ho nab jen kompenzuje vlastn ztr ty baterie Vyrovn vac nab jen zaji uje vyrovn n rozd l v konu v r mci bateriov ch l nk P eru en nab jen odpojen baterie Nebezp...

Page 41: ...y parametr nab je ky jsou chybn P stroj je vadn Zavolejte servis E5 Servis Hodnoty parametr nab je ky jsou chybn P stroj je vadn Zavolejte servis E6 Chyba testu Test p stroje byl z d vodu chyby p eru...

Page 42: ...PzS RUS 43 v014r0 l C A 10 40 C 95 1 IP21 65 A 1 z z z A A z z A z z z z z z z LED 5 60 5 Aquamatic aquamatic 16...

Page 43: ...PzS RUS 44 v04r0 STOP 2 8 3 5 z z z z 8 1 z 3 100 z z z 1 STOP 2 STOP 5 EUW 5 1 3 100 4 5 12 IRComm 7 AGL 8 STOP 6 30 E12...

Page 44: ...PzS RUS 43 v014r0 80 100 8 F0 U 2 0 V Z 1 2 0 F3 U 1 5 V Z 1 5 F4 U 2 4 V Z 2 4 F7 U 2 48V Z 5 E2 E3 E5 E6 E11 I 0 A 4 E12 EUW E13 I 125 125 E20 U 1 V Z 1 V Z E21 E30 I 2 2 z z...

Page 45: ...vaid vastava v lja ppega elektrik z V rgukaitse peab vastama andmesildil toodud v rtusele vt lk a z Elektriala spetsialist peab kindlaks tegema v rgupinge vastavuse andmesildil toodud v rtustele Akup...

Page 46: ...slaadimise k igus kontrollitakse ksikute elementide mahutavuse erinevust Laadimiskatkestuse puhul hendage aku lahti Plahvatusoht z Elektris deme v ltimiseks ei tohi kunagi eraldada laadimispistikut la...

Page 47: ...utuli 5 laaduri h ire Valeteave Vale kirjeldus Abiteave E2 Seadme andmed Laadurri seadistused on valed Seadistage akulaadur uuesti v i p rduge hoolduskeskuse poole E3 Hoolduskeskus Laaduri seadistusan...

Page 48: ...i typeserien MasterLine oppfyller kravene til CE merking Forskrifter elektromagnetisk kompatibilitet direktiv 2004 108 EC EN61000 6 4 2002 EN61000 6 2 2006 EN 61000 3 2 2006 lavspenning direktiv 2006...

Reviews: