Part B: Terminating 501/RCG Body
Seal/Ring Size
Dim
Os-A
B
y
50mm min
25mm
20mm
x
Strip Lengths
Armour Clamp Ring Orientation
Gland
Size
Os-A
Orientation
0 - 0.8mm
0.8 - 1.25mm
B
0 - 0.7mm
1.25 - 1.6mm
Equipment Side
Equipment Side
x
Tape Armour
After tape is spread, ensure ends are
trimmed at 90° as shown
STEP B1: Prepare Cable
Slide backnut (12), middlenut (11) and armour clamp ring (10) onto cable.
Confirm orientation of armour clamp ring is correct (see table below).
Cut cable length, strip outer sheath and cut armour. Use lengths as shown in table below.
x
y
STEP A6: Complete wiring of conductors
Installation of the 501/RCG Entry to the equipment is now complete. Proceed to terminate the conductors inside the equipment as
required.
Once installation is complete, the 501/RCG Entry may be terminated in one of the following ways:
-Fit transit cap for environmental protection
- Fit Entry Energised End Cap which may allow product to be energised (See Part D)
- Mate Entry with 501/RCG Body (See Part C)
STEP A5: Fit crimped conductors into entry
Using the insertion tool supplied with the product, push the pin contact into the entry (2) until it clicks
into place. Repeat for all contacts. Inspect contacts to ensure they are straight - if needed adjust with the
insertion tool.
NOTE: The ground contact sits higher than the signal positions as it is designed to mate first/break last.
EQUIPMENT
EQUIPMENT
*Click*
AI 2045 - Issue B / Page 3 of 9
Images for illustration purposes only.
Product supplied may differ from that shown.