8
Troubleshooting
Fault
Possible cause
Remedy
Hydraulic uid level too low (foaming hydraulic uid)
►
"Filling hydraulic uid", page 50
Excessive noise production
Pump/motor faulty
Hydraulic power pack
►
Shut down
►
Repair or replace
Faulty connections
►
Check connections
►
"Visual check: Hydraulic lines (pipes and hoses)",
page 49
Pump/motor faulty
Hydraulic power pack
►
Shut down
►
Repair or replace
Delivery ow direction wrong
►
"Setting pump’s rotation direction", page 45
Insufficient or no pressuri-
sation
Deviations of the pressure specifications
►
"Get in touch with manufacturer", page 60
HAWE Hydraulik SE
B 8010 - 04-2021 - 1.0
53/61