Havahart SS-725 Operation And Installation Instructions Manual Download Page 4

TROUBLESHOOTING GUIDE

Fact: The large majority of all fence energizers returned for repair are not

defective. The problem is usually in the fence construction.

If the fence is not operating properly, check the fence line to make sure it is not

touching your house, trees, shrubs, grass weeds or anything other than the plastic
fence posts. These will all cause the fence to short out. Check your connections to the
power source to see that they are secure. Be sure the fence and ground wires are
tightened securely by the wing nuts. If everything checks out and you still do not have
a "sting" on the fence line, you may have a poor ground, in which case you may need
to drive a 6–8' (1.8–2.4 m) metal rod into the earth and replace the ground wire from
the two-foot ground rod to the new rod (see Illustration 2). If you suspect there is no
charge from the energizer, perform the following test. 

BE CAREFUL NOT TO TOUCH

THE ACTIVATED FENCE WIRE.

Use a commercial electric fence tester to check the

output on the fence line while it is activated. If there is no output, remove the fence wire
from the energizer and check the output across the terminals with an electric fence
tester. If the tester indicates output, the problem is with the fence. If the tester indicates
no output, the problem is with the energizer.

SS-725

: The output of this energizer can be checked using an AC voltmeter. The

open circuit (no load) output is between 700 and 900 volts AC. The amperage at short
circuit conditions (maximum) is 6 to 10 milliamperes.

SS-750

: The indicator lamp (located between the ground and fence terminals)

shows the output to be OK when the lamp blinks under normal fence load conditions.
If the lamp does not blink, remove the fence wire from the energizer to see if the lamp
begins to blink at no-load conditions. If the lamp does blink, the problem is with the
fence construction. If the lamp does not blink, the problem is with the energizer. 

CAUTION: Always unplug the energizer from its power source when discon-

necting the fence wire.

The SS-750 energizer's output can only be measured using

a commercial type electric fence tester.

HOW AN ELECTRIC FENCE WORKS

Illustration 2 depicts a typical electric fence circuit. When an animal comes into con-

tact with an electrically-charged fence, the animal will feel the electric current because
the electrical charge passes through the animal's body, then through the earth to the
ground rod, and then up the ground wire to the ground terminal of the energizer. If the
animal and the ground terminal of the energizer are not sufficiently grounded due to an
improperly installed ground rod or fence system, or if the animal is not grounded, then
the path of electric shock cannot be completed and the animal will not feel the charge. 

4

ENGLISH

305-165S-REV 10_18_06.qxd  1/14/2008  10:44 AM  Page 4

Summary of Contents for SS-725

Page 1: ...305 165S REV 10_18_06 qxd 1 14 2008 10 44 AM Page 1...

Page 2: ...rmful electric shock on the electrified fence 10 Repair of the electric fence energizer should be performed by an authorized repair center only For the nearest repair center in your area call 1 800 80...

Page 3: ...y fastened to the post Thread the wire through the cotter pin as shown in the illustrations NOTE THE COTTER PIN WILL BECOME HOT WHEN THE ENERGIZER IS ACTIVATED You may also simply thread the wire thro...

Page 4: ...e output of this energizer can be checked using an AC voltmeter The open circuit no load output is between 700 and 900 volts AC The amperage at short circuit conditions maximum is 6 to 10 milliamperes...

Page 5: ...e poor soil and earth grounding condi tions exist Note Animals that are prone to jumping may be difficult to confine You may need to try different heights and or fence configurations in order to deter...

Page 6: ...purchaser against defects in materials and workmanship This war ranty does not cover fuses or circuit breakers where applicable This warranty does not cover damage to the energizer caused by storms li...

Page 7: ...cionar como conector a tierra de este producto Una falla interna en un energizador de cerca incorrectamente conectado a tierra podr a producir una peli grosa descarga el ctrica en la cerca electrifica...

Page 8: ...alimentaci n a un tomacorriente normal Si usa una extensi n aseg rese de que sea la apropiada para la aplicaci n INSTALACION DE LA CERCA Introduzca los postes en la tierra a una profundi dad de 7 6 1...

Page 9: ...A GRAN MAYOR A DE LOS ENERGIZADORES PARA CERCAS DEVUELTOS PARA SER REPARADOS NO SON DEFECTUOSOS NORMALMENTE EL PROBLEMA TIENE QUE VER CON LA CONSTRUCCI N DE LA CERCA Si su cerca no funciona correctame...

Page 10: ...on bien conectados a tierra porque la varilla de tierra o el sistema de cerca instalado no ha sido conectado correctamente o si el animal no est bien a tierra entonces el circuito de la corriente el c...

Page 11: ...ica porque est tocando s lo el alambre de la CERCA o alambre energizado el cu l no est conducido a tierra NOTA Si ha instalado una varilla de tierra de dos pies y no obtiene una descarga el ctrica ade...

Page 12: ...E LA COMPRA GARANT A LIMITADA No hay otra garant a expresa para este energizador Ni Woodstream ni el vendedor ser n responsables de da os incidentales o conse cuentes que surjan del uso o p rdida de u...

Reviews: