49
S2
(1) (0)
4
3
2
1
S2
(1) (0)
4
3
2
1
S2
(1)
(0)
1 2 3 4
*
ON
OFF
ON
OFF
ON OFF
ON OFF
Check / Adjust DIP switch
Slide sash into centered position
AUF
ZU
Example:
left version (sliding sash opening from the left
to the right - drive right, view from inside)
The running direction has to be checked before initialization!
(Condition upon delivery)
Example:
right version (sliding sash opening from the
right to the left - drive left, view from inside)
AUF
ZU
System adjustments ( = applicable)
ON
(1)
OFF
(0)
1
left version
right version
2
Secondary (Scheme C)
3
Primary (Scheme C)
4 automatic / optional with
finger print sensor (ekey)
DEAD-MAN‘s mode ** / with key switch
**) In case of first start-up (‘Full-Init’) or teach-in run
(‘Home-Init’), the sash runs in AUTOMATIC mode and
afterwards in DEAD-MAN‘s mode.
Press button ‘OPEN’: the sliding sash has to run
‘OPEN’� The sash runs approx� 100 mm and then
stops automatically� If the sash does not run ‘OPEN’,
on S2 the DIP-switch 1 has to be set ‘0’ (OFF)�
*) in case of 1-button control pushbutton, the available
button will be pressed
at least 20 seconds
After changing the S2 switch, the power supply unit
must be disconnected from the power supply for at
least 20 seconds.
Slide sash into centered position