• If the extension cord is worn, cut or damaged in any
way, replace it immediately.
Extension Cord Length
Wire Size…………….............................................. A.W.G.
Up to 25 ft (7.5 m)……………...............................12 gauge
25-50 ft (7.5 - 15 m)……………............................10 gauge
NOTE:
Using extension cords over 50 ft. (15 m). long is
not recommended.
ELECTRICAL CONNECTIONS
All electrical connections must be performed by a
qualified electrician.
Make sure tool is off and disconnected from power source
while motor is mounted, connected, or any time wiring is
inspected.
Motor and wires are installed as shown in wiring diagram
(see Figure 8). Motor is assembled with approved, 3-con-
ductor cord to be used at 115 volts. Motor is prewired at
the factory for 115 volts.
Drum Sander has a locking rocker switch with removable
key for safe and easy operation.
• Remove the key from the locking rocker switch to
prevent unauthorized use of the tool.To replace the key,
press key into the slot on the locking rocker switch.
Drum sander also has a manual reset overload protector
to prevent damage to motor and other electrical
components. The overload protector will get activated
when high current is detected while operating the tool.
This will turn the tool off to prevent damage. If that occurs,
turn sander “OFF” and depress the reset button once. The
tool will be ready to continue operation.
24
Circult Breaker
Line Cord
Switch
Ground
Motor
Figure 8 -
WARNING
WARNING