6. FAULT DIAGNOSTICS
Before performing any work on the tool, ensure that it is disconnected from the mains.
ATTENTION: If you should require any service other than those detailed below, please consult the nearest Technical
Service Centre.
In all cases, we would advise sending the machine to the nearest Technical Service centre for repair.
Always use original spares. Any other part type could seriously damage the tool and would void the guarantee.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The tool does not move, moves
slowly or jumpily forwards
Air in the system
Hold the pressing head upright an press the
operating buttons for feed and the release valve
simultaneously for around 10 seconds
Oil level low
Fill oil in accordance with the instructions above
Cylinder piston jammed
Check the cylinder for damages.
Contact [email protected]
Leaks on the installed pump
Contact [email protected]
The tool does not move, only
partially or moves slowly
Air in the system
Bleed as described above
Return spring damaged or other
damage to the cylinder
Contact [email protected]
Oil loss at piston
O-rings damaged
Contact [email protected]
Crimp process is not completed or
does not return to the basic
position
Battery is not sufficiently charged,
therefore there is not sufficient
hydraulic energy to release
Insert the replacement battery. Ensure that the
replacement battery is always charged.
CAUTION:
Pushing the operating button too firmly
may cause damage to the release valve.