A
B
C
D
E
F
G
H
I
179
4000328140 E01.15
AUS
Telescopic handlers
H
- Lubrication and maintenance
12.6.2 - Checking the level of the rear axle
Capacity :
• Rear axle : 8,5 l(2,24 gal US).
• Before performing the oil replacement operations, firstly remove the drain plugs ( 2 ) to eliminate any
pressure from inside the housing.
• Loosen the control plug ( 1 ).
• The lubricant level in the axle must be at the level of the control plug ( 1 ), otherwise top up to the
correct level via the same hole.
• Refit the control plugs ( 1 ) and the drain plugs ( 2 ).
Section H 18.2 - Refer to the Lubricants and equivalents table for the type of oil used.
• Take advantage of this operation to clean the control plugs ( 1 ) and the drain plugs ( 2 ).
12.6.3 - Checking the level of the epicycloidal reducers
N.B.
-:-To check the reducer oil level, you must move the machine to position the closure plug in the
required positions. Due to the presence of the differential on each of the axles, you will have to repeat
this operation individually for each of the machine wheels.
Capacity : 4 x 1,3 l(4 x 0,34 gal US)
• When it is in the high position, loosen the plug ( 3 ) by a few turns, to release any internal pressure
from the housing and then close it again.
• Drive the machine slowly to bring the plug to horizontal position.
• Loosen the plug completely : the oil level must arrive at the plug, otherwise top up to the correct level
via the same hole.
• Refit the plug ( 3 ).
Section H 18.2 - Refer to the Lubricants and equivalents table for the type of oil used.
1
2
3
3
Summary of Contents for HTL 3010
Page 2: ...2 4000328140 E01 15 AUS Telescopic handlers ...
Page 8: ...8 Operator s manual ...
Page 12: ...12 4000328140 E01 15 AUS Telescopic handlers ...
Page 80: ...80 4000328140 E01 15 AUS Telescopic handlers D Operation ...
Page 114: ...114 4000328140 E01 15 AUS Telescopic handlers G Technical characteristics ...
Page 222: ... LECTRICAL IAGRAM 4ELESCOPIC ANDLERS ...
Page 223: ... YDRAULIC IAGRAM 4ELESCOPIC ANDLERS 4 4 4 107P315160 D ...