Operation and maintenance
28
Caution!
After an incident, inspect the
machine carefully and test all the
functions. Only lift the platform after
checking that all damage has been
repaired and that all commands
work properly.
THE MANUFACT
URER MU
ST BE INFORMED
IMMEDIATELY OF ANY INCIDENT INVOLVING A QUICK-
UP, E VEN IF N O MATER IAL DAMAGE OR IN JURY IS
CAUSED.
5.1.1 - Periodical servicing
IMPORTANT: IF USING "ORGANIC" OR "EXTREME COLD" OIL, THE
PRERIODICITIES INDICATED BELOW SHOULD BE HALVED .
• Collect old oil to prevent environmental pollution.
NOTE:
Maintenance personnel must refer to the requirements of lo-
cals standards, in regard to the general and 10 year inspec-
tion requirement which apply to this product.
PERIODICITY
OPERATION
Before use
• Check all the machine’s safety systems
Every day
• Check:
- that there are no oil le aks (traces on the g round under the
parked machine)
- that the mast pad slide paths are clean
- the condition of protections
- the condition of welding
- the electric connections and battery power cables
- the stabliser bars and their blocking pins
- the manual lowering valve
Every week
• Visually check
- the battery level. If necessary, top up with distilled water, only
after charging
- the condition of the cables.
• If necessary, clean and/or oil the masts and cables.
Every 3 months
• Check:
- battery density
- masts
- platform
- control boxes
- platform overload
• Oil the mast chains
• Check tightness of wheels, hydraulic connectors and bolts
Every 6 months
• Change the batteries
Every year
• Check:
- Perform a co mplete check of ma sts an d/or co ntact the
manufacturer and/or distributor
- Electric connections.
• Empty the hydraulic tank and change the oil.
• Have the machine examined by a certified inspection organisa-
tion (Order dated March 15th 2004)
Summary of Contents for Quick Up 11
Page 2: ......
Page 4: ......
Page 8: ...Operation and maintenance ii...
Page 12: ...Operation and maintenance vi...
Page 26: ...Operation and maintenance 14...
Page 28: ...Operation and maintenance 16...
Page 44: ...Operation and maintenance 32...
Page 46: ...Operation and maintenance 34...
Page 47: ...Operation and maintenance 35 7 HYDRAULIC DIAGRAM 7 1 AC VERSION...
Page 48: ...Operation and maintenance 36 7 2 DC VERSION...
Page 49: ...Operation and maintenance 37 8 WIRING DIAGRAMS 8 1 AC VERSION...
Page 50: ...Operation and maintenance 38 8 2 DC VERSION...
Page 51: ...39 9 REGISTER OF INSPECTION AND REPAIR Date Comments...
Page 52: ...40 Date Comments...