INSTALLATION
Form No. UGAM-0908
17
Power Supply
Install supply wire and connectors suitable for at least
90°C (194°F).
• Use a minimum of No. 14 AWG copper wire for
individual circuits up to 15 amps.
• Use a minimum of No. 12 AWG copper wire for
individual circuits 15 to 20 amps.
• Use a minimum of No. 10 AWG copper wire for
individual circuits 20 to 25 amps.
NOTE: Refer to the wiring diagram supplied with
the unit and specifications label attached to
the unit for specific electrical information.
Conduit Connection
Units supplied with a right
angle fitting and flexible
conduit attached have had all
internal
connections
completed at the factory.
Attach the proper power
supply leads to the high
temperature lead wires in the
conduit.
Figure 17. Conduit
NOTE: Refer to the wiring diagram supplied with
the unit and specifications label attached to
the unit for specific electrical information.
Conduit
Fitting
Remote Control Enclosures
Hatco Remote Control Enclosures (RMBs) include
switches, wire leads, and/or indicator lights and are
ready for installation. Proper use of RMBs require
one RMB per strip heater.
To prevent premature failure of components due
to excessive heat, remote control enclosures
must be installed outside the strip heater heat
zone.
Control Switches
When two or more units are mounted where the
heat from one housing tends to raise the
temperature of another, the control switches should
be installed in a remote control enclosure. Units in a
multiple installation should use remote control
enclosures.
NOTE: Remote control enclosures are available in
several sizes. All models are built in
accordance with UL standards to
accommodate switches, indicator lights,
and wiring, ready for installation. See the
OPTIONS
section near the back of this
manual.
NOTICE
OPERATION
General
Use the following information to operate the
Ultra-Glo
®
Strip Heaters.
Read all safety messages in the IMPORTANT
SAFETY
INFORMATION
section
before
operating this equipment.
Standard and approved manufacturing oils may
smoke up to 30 minutes during initial startup.
This is a temporary condition. Operate unit
without food product until smoke dissipates.
Heating Element(s)
Heating element(s) are controlled either by an
ON/OFF toggle switch(es) or an optional infinite
control(s). To turn each element on, move the
ON/OFF toggle switch to the ON position or turn the
infinite control to the desired setting. If the unit is
equipped with an indicator light(s), the light(s) will
illuminate when the element is turned on.
Allow 15-20 minutes to reach operating temperature.
CAUTION
WARNING
BURN HAZARD: Some exterior surfaces on the
unit will get hot. Use caution when touching
these areas.
NOTE: Units with factory attached control boxes
cannot be equipped with infinite switches.
Lights
On models equipped with display lights, move the
light ON/OFF toggle switch to the ON position to turn
on the lights.
Figure 18. Controls
CAUTION
ON/OFF
Toggle Switch
Indicator Light
Electronic Infinite Control