background image

Form No. TMSCEM-0615

7

INSTALLATION

Wall Installation

1. Install the wall mount bracket provided with the unit onto a

solid,  non-combustible  surface  using  the  appropriate

fasteners. There are five mounting holes on the wall mount

bracket.

• Make  sure  the  fasteners  are  appropriate  for  the

installation surface and the weight of the unit.

• locate the unit directly underneath an exhaust hood if

possible.  This  will  ensure  total  suction  of  steam

produced during cooking.

• Make sure the unit is at the proper height in an area

convenient for use.

2. align the mounting slots on the back of the unit with the

hooks on the wall mount bracket. Set the unit on the hooks.

Mounting Slots on Back of Unit

3. Have a qualified electrician perform the necessary electrical

connections (refer to “Electrical Connections” in this section

for additional information).

Electrical Connections

The  THERM-Max Salamander  must  be  hardwired  to  the

electrical  supply  or  have  the  appropriate  cord  and/or  plug

installed.

ELECTRIC SHOCk HAzARD:

• Units supplied without an electrical plug require field

installation  of  proper  plug.  Plug  must  be  properly

grounded  and  of  correct  voltage,  size,  and

configuration  for  electrical  specifications  of  unit.

Contact a qualified electrician to determine and install

proper electrical plug.

• Units  supplied  without  an  electrical  cord  and  plug

require field installation of proper cord and plug or a

hardwired  connection  to  on-site  electrical  system.

Connection must be properly grounded and of correct

voltage,  size,  and  configuration  for  electrical

specifications of unit. Contact a qualified electrician to

determine and install proper electrical connection.

• When installing a hardwired unit, a 2-pole or 3-pole

switch (depending on unit) must be installed between

unit and main electrical supply. The switch must be

rated  properly  and  have  contacts  with  a  minimum

opening distance of 3 mm (1/8″).

• Unit must be connected to an equipotential system that

complies with the latest electrical standards.

Mounting Slots

WARNING

Make  sure  electrical  supply  matches  the  voltage  and

frequency  rating  on  the  specification  label.  Incorrect

electrical supply may damage the unit.

Hardwired Connection

1. Remove the access panel to expose the power inlet area of

the unit. It is located on the right rear side of the unit when

facing the controls.

location of Power Inlet

2. locate the terminal block inside the unit.
3. Bring power leads from a properly sized circuit breaker or

disconnect switch through the power inlet on the unit.

4. Make the appropriate connections. 

• Use copper wire only.
• Tighten  connections  to  a  minimum  of  4.25  newton

meters (40 inch pounds).

• a  grounding  screw  is  provided  near  the  electrical

terminals. an equipment grounding conductor must be

properly connected to it.

5. Replace and secure the access panel.

Cord and Plug Connection

On units supplied with a power cord, connect the proper plug to

the cord. Make sure the plug is rated for the specific load and

the plug matches a suitable receptacle.

NOTE: The specification label is located on the side of the unit

near the power inlet. See the label for verification of unit
electrical information.

NOTE: The  plug  and  receptacle  must  be  grounded  in

accordance with current standards.

Power Inlet

Access Panel

NOTICE

Summary of Contents for TMS Series

Page 1: ... Regístrese en línea Fornello portatilei Serie TMS Manuale per l installazione e l uso P 46 Registratevi online Salamander Serien TMS Installations und Bedienungshandbuch P 13 Registrieren Sie sich online Salamander Séries TMS Manuel d installation et d utilisation P 35 S inscrire en ligne Register Online see page 2 hatcocorp com Original Instructions Originalanleitung Instrucciones originales Ins...

Page 2: ...ng Chart 5 Dimensions 5 Installation 6 General 6 Countertop Installation 6 Wall Installation 7 Electrical Connections 7 Operation 8 General 8 Control Panel 8 Operating the Salamander 9 Maintenance 10 General 10 Daily Cleaning 10 Troubleshooting Guide 11 International Limited Warranty 12 Service Information 12 IMPORTANT OWNER INFORMATION Record the model number serial number voltage and purchase da...

Page 3: ...codes Installation by unqualified personnel will void unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings Units supplied without an electrical plug require field installation of proper plug Plug must be properly grounded and of correct voltage size and configuration for electrical specifications of unit Contact a qualified electrician to determine...

Page 4: ...ements are strategically positioned inside the moveable upper housing to reduce the transfer of heat to the surrounding area The HOlD function on TMS 1H models is ideal for keeping foods hot or reheating foods a removeable cooking grate and drip tray allows for easy cleanup The unique features and flexibility of the THERM Max Salamander make it easy to operate energy efficient and highly functiona...

Page 5: ... lbs Model Width A Depth B Height C Footprint Width D Footprint Depth E Cooking Width F Cooking Depth G Cooking Height H TMS 1H and TMS 1 600 mm 23 5 8 510 mm 20 1 8 546 mm 21 1 2 520 mm 20 1 2 380 mm 15 540 mm 21 1 4 365 mm 14 5 16 50 to 212 mm 2 to 8 1 4 SPECIFICATIONS Electrical Rating Chart NOTE Shipping weight includes packaging Dimensions Form No TMSCEM 0615 5 Front View Side View A F F F D ...

Page 6: ...hould be level to prevent unit or its contents from falling accidentally and strong enough to support the weight of the unit and contents Do not place anything on top of unit doing so may subject personnel to injury or damage unit NOTE A qualified person must check possible placements of the salamander to ensure that the proper electrical supply line is available 1 Remove the unit from the shippin...

Page 7: ...n for electrical specifications of unit Contact a qualified electrician to determine and install proper electrical connection When installing a hardwired unit a 2 pole or 3 pole switch depending on unit must be installed between unit and main electrical supply The switch must be rated properly and have contacts with a minimum opening distance of 3 mm 1 8 Unit must be connected to an equipotential ...

Page 8: ...king Grate Control Panel Height Gauge Heating Mode Selector The heating mode selector determines the function of the overhead elements in the salamander The operation of this knob is slightly different for each model TMS 1H Models The heating mode selector on TMS 1H models has five positions and two functions COOK and HOlD The following are descriptions of the five positions OFF No elements select...

Page 9: ... product onto the cooking grate 3 Turn the heating mode selector to the desired COOK function The ON indicator light will illuminate 4 Turn the timer knob clockwise to the desired cooking time The appropriate lEFT and or RIGHT indicator light s will illuminate to indicate which elements are selected and heating Operating the Salamander NOTICE Place food product onto cooking grate Lower upper housi...

Page 10: ...perate safely in Hatco equipment This unit has no user serviceable parts If service is required on this unit contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 414 671 6350 fax 414 671 3976 WARNING Daily Cleaning To preserve the finish of the unit as well as maintain performance it is recommended that the unit be cleaned daily Use non abrasive cleaners and cloths ...

Page 11: ... to trip contact an authorized Hatco Service agent or Hatco for assistance Timer or Heat Mode switch defective Contact an authorized Hatco Service agent or Hatco for assistance Form No TMSCEM 0615 11 TROUBLESHOOTING GUIDE This unit must be serviced by qualified personnel only Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC SHOCk HAzARD Turn OFF power switch unp...

Page 12: ...or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely to replacement of part or Product using at Hatco s option new or refurbished parts or Product by Hatco or a Hatco authorized service agency with respect to any claim made within the applicable warranty period referred to above Hatco reserves the ri...

Page 13: ...iel Alternating Current Corriente alterna Courant Alternatif Water Fill Low Water Llenado de agua bajo nivel de agua Remplir d eau Bas Niveau d eau Humidity Humidity Cycle Humedad ciclo de humedad Humidité Cycle Humidité Symbolerklärung Identificazione del simbolo Uitleg bij de symbolen Achtung Heiße Oberfläche Attenzione superficie calda Let op heet oppervlak Einschalten Acceso Ingeschakeld Aussc...

Reviews: