P.O. Box 340500
Milwaukee, WI 53234-0500 U.S.A.
(800) 558-0607 (414) 671-6350
www.hatcocorp.com
E-mail: [email protected]
Printed in U.S.A.
Form No. GWHB-1597-3
Revised March 2003
24
5
/
8
"
(63 cm)
18
5
/
8
"
(48 cm)
20
3
/
8
"
(52 cm)
Alternate
TPRV on back
TPRV
24
1
/
2
"
(62 cm)
6" (15 cm)
FRONT VIEW
RIGHT SIDE VIEW
Electrical
31
1
/
4
"
(79 cm)
25
1
/
4
"
(64 cm)
27
1
/
2
"
(70 cm) PMG-100
36" (91 cm) PMG-200
20
3
/
4
"
(53 cm)
6" (15 cm)
REAR VIEW
RIGHT SIDE VIEW
Water
Outlet
Water
Inlet
Gas
Inlet
Alternate
Flue
Location
TPRV
4" (10 cm)
Vent Adapter
Water Outlet
Water Inlet
Gas Inlet
31
1
/
4
"
(79 cm)
27
1
/
2
"
(70 cm) PMG-100
Water Outlet
Electrical
Electrical
Water Inlet
Gas Inlet
36" (91 cm) PMG-200
20
3
/
4
"
(53 cm)
25
1
/
4
"
(64 cm)
6" (15 cm
)
FRONT VIEW
LEFT SIDE VIEW
Water
Outlet
Water
Inlet
Gas
Inlet
Alternate TPRV
Location
TYPICAL SINGLE POWERMITE PMG-60 GAS BOOSTER WATER HEATER INSTALLATION
POWERMITE PMG-100 & PMG-200 BOOSTER HEATERS
Take the
ENERGY AUDIT
on our website:
www.hatcocorp.com
3
⁄
4
" Gate or Ball Valve* Temperature/Pressure Gauge
Pressure Reducing Valve w/By-Pass Blended Phosphate Water Treatment System
Temperature/Pressure Relief Valve Alternate TPRV Location Out Rear of Unit
Shock Absorber Union* Drain Pipe Valve*
INLET
Maximum
160
°
F. (71
°
C)
Inlet Temperature
DRAIN
1
3
2
2
7
7
7
7
8
4
5A
5B
6
PLUMBING
DISCHARGE PIPE
TO FLOOR DRAIN
OUTLET
4
2
1
*Supplied by installer
3
6
7
8
5A
5B
INLET
OUTLET
GAS BOOSTER WATER HEATER SPECIFICATIONS
* Based on performance at sea-level to 2,000 ft. (610 m). Above 2,000 ft.
(610 m) performance may vary, consult factory.
FLUING:
Direct – combustion air enters bottom, flue gasses exit both
sides at top of unit.
ELECTRICAL POWER:
Supply 120 VAC, 210 watt, 1.75 amp.
CONNECTIONS:
Gas –
1
/
2
” NPT, Water –
3
/
4
” NPT,
Electric – 120 VAC, 15 amp.
SHIPPING WEIGHT:
130 lbs. (59 kg) dry.
* Based on performance at sea-level to 2,000 ft. (610 m). Above 2,000 ft.
(610 m) performance may vary, consult factory.
FLUING:
Direct – combustion air enters bottom, flue gasses exit
right side or back at top of unit. 4" (10 cm) flue round.
EXHAUST VENT:
Forced draft system with 4" (10 cm) diameter
vent pipe adapter to meet regulatory and
local codes.
ELECTRICAL POWER:
Supply 120 VAC, 360 watt, 3.00 amp.
CONNECTIONS:
Gas –
3
/
4
” NPT, Water –
3
/
4
” NPT,
Electric – 120 VAC, 15 amp.
SHIPPING WEIGHT:
PMG-100 – 180 lbs. (82 kg) dry.
PMG-200 – 215 lbs. (98 kg) dry.
CONSULT LOCAL CODES
POWERMITE PMG-60 BOOSTER HEATER
1
2
3
4
GAS PIPING
3
1
Manual Shut-off Sediment Trap Union
Gas Line Enters Base Connecting to Combination Valve
2
4
24
3
/
8
" (62 cm)
6
7
/
8
"
(18 cm)
4" (10 cm)
diameter
flue
adapter
FRONT VIEW
See Specification Sheet
for exact plumbing
and gas connection
locations and drawings
of other models.
POWERMITE PMGH-60 HOOD
•
Input
Gallons per Hour, GPG (LPH),
Model
MBH (1,000
at Indicated °F. (°C) Temperature Rise*
BTU/HR)
30° (16°)
40° (22°) 50° (28°) 60° (33°)
70° (39°)
PMG-60
58
181 (685)
135 (511)
108 (409)
90 (341)
77 (292)
Input
Gallons per Hour, GPG (LPH),
Model MBH (1,000
at Indicated °F. (°C) Temperature Rise*
BTU/HR)
30° (16°) 40° (22°) 50° (28°) 60° (33°)
70° (39°)
PMG-100
105
321 (1215)
241 (912)
193 (731)
161 (610)
138 (522)
PMG-200
195
602 (2279) 452 (1711) 361 (1367) 301 (1139)
258 (977
)
WATER QUALITY REQUIREMENTS
Incoming water in excess of 3.0 grains of hardness per gallon (GPG) (.75 grains of hardness per liter) must be
treated and softened before being supplied to booster heater(s). Water containing over 3.0 GPG (.75 GPL) will
decrease the efficiency and reduce the operating life of the unit.
Note: Product failure caused by liming or sediment buildup is not covered under warranty.
ANSI/NSF 5
• Add 4" (10 cm) to width and 5
7
/
8
"