background image

Form No. IRGCEM-1010

2

CONTENTS

This  manual  provides  the  installation,  safety,  and  operating

instructions for Hatco Induction Griddles. Hatco recommends all

installation, operating, and safety instructions appearing in this

manual be read prior to installation or operation of a unit. 

Safety information that appears in this manual is identified by

the following signal word panels:

WARNING  indicates  a  hazardous  situation  which,  if  not

avoided, could result in death or serious injury.

CAUTION  indicates  a  hazardous  situation  which,  if  not

avoided, could result in minor or moderate injury.

NOTICE is used to address practices not related to personal

injury.

NOTICE

CAUTION

WARNING

INTRODUCTION

Hatco  Induction  Griddles  offer  a  safe,  quick,  efficient,  and

attractive way to prepare foods in commercial kitchens as well

as display cooking locations (omelet bars, buffets, etc...). The

high efficiency, accuracy, and speed of induction cooking make

Hatco  Induction  Griddles  the  perfect  choice  for  quality

foodservice organizations.

Induction  cooking  relies  on  the  creation  of  a  magnetic  field

between the induction coils and a magnetic material (ferrous

material)—the  composite  metal  (ferrous  stainless  steel  and

aluminum)  griddle  surface  of  the  unit.  This  magnetic  field

generates  induction  currents  in  the  griddle  surface,  which

creates instant heat. That heat then is transferred directly to the

food product on the griddle. When the magnetic field is “broken”

by turning off the unit, heat generation stops instantly.

Hatco Induction Griddles are products of extensive research

and  field  testing.  The  materials  used  were  selected  for

maximum  durability,  attractive  appearance,  and  optimum

performance. Every unit is inspected and tested thoroughly

prior to shipment.

Important Owner Information ..............................................2

Introduction...........................................................................2

Important Safety Information...............................................3

Model Description.................................................................4

Model Designation................................................................4

Specifications........................................................................5

Plug Configurations .........................................................5

Electrical Rating Chart.....................................................5

Dimensions......................................................................5

Installation .............................................................................6

General............................................................................6

Operation...............................................................................7

General............................................................................7

Maintenance ..........................................................................8

General............................................................................8

Daily Cleaning .................................................................8

Cleaning the Air Inlet Filters ............................................9

Troubleshooting Guide ......................................................10

Limited Warranty.................................................................11

Service Information ............................................................11

IMPORTANT OWNER INFORMATION

Record  the  model  number,  serial  number  (located  on  the

bottom of the unit), voltage, and purchase date of the unit in

the spaces below. Please have this information available when

calling Hatco for service assistance.

Model No. ____________________________________

Serial No. ____________________________________

Voltage ______________________________________

Date of Purchase ______________________________

Register your unit!

Completing online warranty registration will prevent delay in

obtaining warranty coverage. Access the Hatco website at

www.hatcocorp.com

, select the 

Parts & Service

pull-down

menu, and click on “Warranty Registration”.

Business

8:00 

AM

to 5:00 

PM

Hours:

Central Standard Time (C.S.T.)

(Summer Hours:  June to September – 
8:00 

AM

to 5:00 

PM

C.S.T. 

Monday through Thursday
8:00 

AM

to 2:30 

PM

C.S.T. Friday)

Telephone: (414) 671-6350

E-mail:

[email protected]

Fax:

(414) 671-3976 (Parts and Service)

Additional information can be found by visiting our web site at

www.hatcocorp.com

.

Summary of Contents for IRG15-3000

Page 1: ...ase bring it to the attention of your supervisor Keep this manual in a safe location for future reference No opere este equipo al menos que haya leído y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte Este manual contiene importante información sobre seguridad concerniente al manteni...

Page 2: ...eration stops instantly Hatco Induction Griddles are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specifications 5...

Page 3: ...electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install the proper voltage and size electrical receptacle Turn power OFF unplug power cord and allow unit to cool before performing any maintenance DO NOT submerge or saturate with water Unit is not waterproof Do not operate if unit has been ...

Page 4: ...re protection to the unit as well as the operators Residual Heat Warning After the unit has been turned off the power indicator light will flash until the griddle surface is cool enough to touch The griddle surface will remain hot for several minutes after an extended period of cooking Auto Stop Function The unit will shut down automatically after an extended period of non use or if the unit is le...

Page 5: ...h contact a qualified electrician to determine and install the proper voltage and size electrical receptacle NOTE The specification label is located on the bottom of the unit See label for serial number and verification of unit electrical information WARNING Figure 3 Plug Configuration NOTE Receptacle not supplied by Hatco BS 1363 NOTE Shipping weight includes packaging Dimensions A G C B D E F Fr...

Page 6: ...e causing injury and or damage to unit Do not block or restrict air flow to air inlet filters or exhaust fan on bottom of unit WARNING CAUTION 1 Remove the unit from the carton 2 Remove the information packet from the carton 3 Remove tape and protective packaging from all surfaces of unit NOTE To prevent delay in obtaining warranty coverage complete online warranty registration See the IMPORTANT O...

Page 7: ...w liquid to run into air inlet filters on bottom of unit WARNING CAUTION Startup 1 Plug the unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration See the SPECIFICATIONS section for details 2 Touch the Button Power On Off to turn on the induction griddle The power indicator light above the Button will illuminate 3 Select the desired heat setting by t...

Page 8: ... NOTE Make sure the grease tray is completely empty before cleaning the griddle surface Use oven mitts to remove and empty if necessary 2 Using oven mitts carefully remove the side shield Clean the side shield after it has cooled 3 Clean the griddle surface a Fill the provided measuring cup with ice cubes and pour directly onto the hot griddle surface The ice helps to loosen cooking residue Do not...

Page 9: ...ir inlet filter a Remove the frame screw on the filter frame b Lift the filter frame and air inlet filter off of the unit c Clean the air inlet filter with soapy water d Allow the air inlet filter to dry completely e Place the air inlet filter inside the filter frame and install onto the bottom of the unit Install the frame by inserting the tabs on the filter frame into the tab slots on the bottom...

Page 10: ...sure installation location allows proper ventilation underneath the unit Make sure air inlet filters and exhaust fan are not blocked Make sure air inlet filters are clean Exhaust fan continues to run after unit has been turned off Cooling of the electronic controls not complete No action necessary This is a normal function of the unit Exhaust fan starts for a few seconds after plugging in unit Aut...

Page 11: ...quest 3CS and FR Tanks c One 1 year Parts and Labor PLUS Nine 9 years Parts Only Warranty on Electric Booster Heater Tanks Gas Booster Heater Tanks d Ninety 90 Day Parts Only Warranty Replacement Parts THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE...

Page 12: ...0 Milwaukee WI 53234 0500 U S A Telephone 414 671 6350 International Fax 414 671 3976 partsandservice hatcocorp com www hatcocorp com hATCO AUThORIzED PARTS DISTRIBUTORS United Kingdom Marren Group Northants 44 0 1933 666233 Register your unit online See IMPORTANT OWNER INFORMATION section for details ...