Form No. HSBFM-1121
9
English
INSTALLATION
9. Locate the remote-mounted control box assembly in
an area that is convenient for operation. If desired or
necessary, the control box can be mounted in a semi-
remote location.
• The control box can be panel, surface, or under counter
mounted. If recess mounting, the control box will require
a mounting cutout of 7-1/4″ W x 3-1/4″ H (184 x 83 mm).
• The distance the control box can be mounted from the
unit is determined by the 3′ (914 mm) conduit (optional
conduit lengths of 6′ [1829 mm] and 10’ [3048 mm] are
also available). Do not pull the conduit tight to increase
the mounting distance. The conduit should have some
slack after the control box is mounted.
Panel
Under Counter
Surface
7-1/4″
(184 mm)
7″
(178 mm)
3″
(76 mm)
3-1/4″
(83 mm)
Control Box Mounting Options
NOTICE
Do not modify wiring or cut thermostat capillary on control
box to increase-remote mounting distance. Cutting the
thermostat capillary will cause the unit to overheat and may
damage the unit as well as the surrounding countertop.
NOTE: The remote-mounted control box should be mounted
using screws with a 1/4″ (6 mm) minimum diameter
screw head inserted through the keyholes located on
the mounting brackets. The control box is to be readily
removable, not permanently mounted.
10. Clean the heated shelf surface thoroughly in preparation
for initial operation. Refer to the MAINTENANCE section
for proper cleaning procedures.
11. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
Countertop
Cutout
Gasket
Inside surface of
mounting bracket
assembly flush with
inside of cutout.
Inside surface of
mounting bracket
assembly flush with
inside of cutout.
Lock Nut
Leveling Bolt
Installing an HSBF Series Heated Shelf