Form No. GRCMWDHHIM-0907
5
INSTALLATION
Figure 5. Installing Breath Protector
Figure 6. Installing Side Glass
ASSEMBLY
Position unit upright on the counter near the location
it will be used. Installation of the Polycarbonate
Breath Protector (Qty. 1), part number
04.12.326.00, is required before operating the unit.
NOTE: Decorative Corian
®
pieces are not supplied
or installed by Hatco.
Installation for Breath Protectors
(On One Door Units Only) (See Figure 5)
1. Remove protective paper from polycarbonate
surfaces.
2. Remove four (4) thumbscrews and washers from
top of unit.
3. Position breath protector on top of unit, matching
holes in breath protector to the holes in the
standoffs on top of the unit.
4. Place a washer (previously removed) in each
breath protector hole.
5. Secure with thumbscrews - Do not over tighten.
Installation for Side Glass (See Figure 6)
1. Remove thumbscrew and upper glass bracket.
2. Insert bottom edge of the side glass panel into
the bottom glass bracket.
3. Ensure the back edge of the glass is against the
vertical support post and tilt the top edge of glass
up against the side of frame.
4. Place upper glass bracket over the top edge of
the glass and secure into place with the
thumbscrew.
4. Repeat steps 1-4 to install glass on opposite
side.
Thumbscrew
Breath
Protector
Washer
Bracket
Side Glass
Standoffs
Thumbscrew