Reversing the Access Door
The Flav-R-Fresh
©
access door(s) may be hinged on either the
left or right side for convenience. Use the following procedure
to reverse the access door.
NOTE: For models equipped with a motorized rotating rack
(FDWD-1, FDWD-2, and FDWD-12), the “Relocating
the Proximity Switch” procedure in this section must be
performed after reversing the access door(s).
1. Remove the top hinge pin screw that holds the door to the
hinge.
2. Tip the door assembly forward (away from cabinet) and lift
gently to clear the bottom hinge assembly. Remove the
nylon washer(s).
3. Reinstall the top hinge pin screw that was removed in Step 1.
4. Remove the fluorescent lamp cover to allow access to the
hinge/striker plate hardware.
5. Remove the screws holding the hinges to the cabinet.
6. Remove the screws from the striker plates on the non-hinge
side of the cabinet.
7. Install the striker plates on the opposite side of the cabinet
where the hinges were previously mounted.
8. Install the hinges on the opposite side of the cabinet where
the striker plates were previously mounted using the original
hinge mounting screws.
9. Replace the fluorescent lamp cover.
10. Carefully rotate the door 180°.
11. Remove the hinge pin screw from the end that is now the
top.
12. Carefully place the door assembly with the nylon washer(s)
into the bottom hinge.
13. Tip/tilt the door assembly towards the cabinet and align the
door top with the hinge. Reinstall the top door hinge pin
screw through the hinge and into the door top.
Hinge Assembly
Bottom Hinge Pin Screw and
Nylon Washer(s)
Door Rotated 180°
Top Hinge
Pin Screw
Lamp
Cover
Striker Plate and
Hardware