background image

18

Form No. F2GPM-0721

English

QR Code Scanner

The QR Code Scanner is available for all units as a factory-

installed option. The QR Code Scanner allows for reduced 

contact during order placement and order pickup. Use the 

following procedures to operate a unit equipped with a QR 

Code Scanner.

Creating a QR Code

When creating a QR Code, use the following data format 

depending on what type of QR Code is being created.

Data Format for the operator to place an order:

ORDER:CREATE:<ORDER NUMBER>:<CUSTOMER NAME>
Example: ORDER:CREATE:11:JOHN DOE

NOTE: The Order Number must be 1 to 6 characters and 

cannot be duplicated on active orders. The Customer 

Name must be 1 to 15 characters and can be duplicated 

on active orders. 

Data Format for the customer to claim an order:

ORDER:CLAIM:<ORDER NUMBER>
Example: ORDER:CLAIM:11

NOTE: The Order Number must be 1 to 6 characters and 

cannot be duplicated on active orders.

Placing an Order Using a QR Code (Operator Side)

Use the following procedure to place a completed and 

packaged customer order into a locker equipped with a QR 

Code Scanner.
  1. On the Select Lockers screen, touch the desired open 

locker number(s).

 

•  Up to four lockers can be selected if the food order will 

not fit in one locker.

  2.  With the locker(s) selected, scan the QR Code.
 

•  If using an electronic device, make sure the phone is 

bright enough for the QR Code scanner to read the code.

Red text indicates

locker is overtime.

White text indicates

time food is

in locker.

Settings

Locker is

disabled.

Order

Code

Locker in

HEATED

mode.

Error

Description of Select Lockers Screen

NOTE: If the order code is currently in use, the unit will not 

accept it. The unit will notify the operator to “Please 

enter a new order code.”

  3. When the Place Order screen appears, place the food 

order into the locker(s) shown on screen.

 

•  The timer will begin to count up on the Select Lockers 

screen. The maximum order time is factory set to 45 

minutes.

Place Order Screen

NOTE: Refer to the “Overtime Order” procedure in the 

OPERATION section for more information about orders 

that stay in a locker past the maximum order time.

Picking up an Order Using a QR Code (Customer Side)

Use the following procedure to unlock and remove food from a 

locker on the customer side using the QR Code Scanner. A general 

outline of this procedure should be provided to the customer.
  1.  On the Orders Ready screen, scan the QR Code.
 

•  If the customer’s name is not shown on the list, their 

order is not ready.

 

•  If the QR Code is scanned correctly, the screen will notify the 

customer to: “Please remove your items from your locker!”

NOTE: If the customer does not remove the food order before 

the door closes, the customer’s name will disappear from 

the list, and an operator will need to remove the order 

manually. 

 

•  If the order code is entered incorrectly, the screen will 

notify the customer “Incorrect QR Code. Please try 

again!” Touch the “OK” button to try again.

Orders Ready Screen

  2.  Remove food from the open locker(s).

OPTIONS AND ACCESSORIES

Summary of Contents for F2GBP Series

Page 1: ...dad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localizaci n s...

Page 2: ...Mount Models 8 Installing Built In Models 9 Operation 10 General 10 Placing an Order 10 Picking up an Order 11 Clear a Single Order 12 Change a Locker s Heated Ambient Setting 12 Change All Lockers He...

Page 3: ...le Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning adjustments or maintenance DO NOT submerge or saturate with water Unit is not waterproof Do not operate...

Page 4: ...AND ACCESSORIES section of this manual for all of the available options and accessories F2GP 21 F2GP 22 and F2GP 12 Models Countertop Models The F2GP 21 F2GP 22 and F2GP 12 models are designed for co...

Page 5: ...d size electrical receptacle NEMA 5 15P Plug Configurations NOTE Receptacle not supplied by Hatco NOTE The specification label is located next to the power cord See the label for the serial number and...

Page 6: ...View Side View A B C SPECIFICATIONS Model Width A Depth B Height C F2GP 21 C 77 3 4 1974 mm 24 11 16 626 mm 16 7 8 428 mm F2GP 22 C 77 3 4 1974 mm 24 11 16 626 mm 31 3 4 804 mm F2GP 12 C 44 1 8 1121...

Page 7: ...mm 2 1 8 54 mm C A B Model Width A Depth B Height C F2GBP 12 C 44 1 8 1121 mm 24 11 16 626 mm 34 3 4 883 mm F2GBP 14 C 44 1 8 1121 mm 24 11 16 626 mm 64 3 8 1635 mm F2GBP 21 C 77 3 4 1974 mm 24 11 16...

Page 8: ...the model and installation type Installing Countertop Models Installing Floor Mount Models Installing Built In Models Installing Countertop Models 1 Place the unit in the desired location Locate the u...

Page 9: ...to 78 1 2 1981 1994 mm 32 to 32 1 2 812 826 mm A B Wall Cutout Dimensions 2 Remove the access panels on the bottom and top of each locker column on the customer side by removing the screws 3 Lift the...

Page 10: ...ON BURN HAZARD Some exterior surfaces on the unit will get hot Use caution when touching these areas 2 For lockers with HEATED mode enabled allow the heated lockers 30 minutes to reach operating tempe...

Page 11: ...e following procedure to unlock and remove food from a locker on the customer side A general outline of this procedure should be provided to the customer 1 On the Orders Ready screen touch the name th...

Page 12: ...rature Ambient selection will turn the heating elements off for that locker No icon will appear next to the locker on the Select Lockers Screen 5 Touch to return to the Select Lockers screen Change Al...

Page 13: ...Lockers screen touch for system settings 2 Enter the Passcode and touch ENTER to access the System Settings screen The factory set Passcode is 88888 3 Touch CLEAR ORDERS All orders will be cleared on...

Page 14: ...he USB slot The software folder must be in the root folder on the USB drive The software will update automatically when the USB drive is inserted USB Slot Touchscreen Controller USB Slot 3 After the t...

Page 15: ...e environments in which they are used Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment This unit has no user serv...

Page 16: ...Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC SHOCK HAZARD Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning adjustm...

Page 17: ...on either side but needs to be installed on the bracket under the touchscreen controller as shown below Side Shelf Mounting Locations Side Shelf Side Shelf Installation 2 Install the circle shelf bra...

Page 18: ...xt indicates locker is overtime White text indicates time food is in locker Settings Locker is disabled Order Code Locker in HEATED mode Error Description of Select Lockers Screen NOTE If the order co...

Page 19: ...armer Elements metal sheathed Drawer Warmer Drawer Rollers and Slides Food Warmer Elements metal sheathed Display Warmer Elements metal sheathed air heating Holding Cabinet Elements metal sheathed air...

Page 20: ...lation des mod les encastr s 28 Mode d emploi 29 G n ralit s 29 Passer une commande 29 R cup rer une commande 30 Effacer une commande unique 31 Modifier le r glage chauff temp rature ambiante d un cas...

Page 21: ...AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspon...

Page 22: ...21 F2GP 22 et F2GP 12 mod les sur comptoir Les mod les F2GP 21 F2GP 22 et F2GP 12 sont con us pour tre utilis s sur un comptoir Ces mod les comportent deux ou quatre casiers de haut avec une ou deux c...

Page 23: ...F2GBP 21 et F2GBP 22 mod les encastr s Les mod les F2GBP 12 F2GBP 14 F2GBP 21 et F2GBP 22 sont con us pour tre encastr s dans un mur Ces mod les comportent une ou deux colonnes et ont une hauteur de...

Page 24: ...Reportez vous l tiquette du num ro de s rie et les donn es lectriques de l appareil Tableau des valeurs nominales lectriques Mod les mont s sur un comptoir Tableau des valeurs nominales lectriques Mod...

Page 25: ...les mont s au sol Vue de face Vue de c t A B C Mod le Largeur A Profondeur B Hauteur C F2GP 21 C 1974 mm 77 3 4 626 mm 24 11 16 428 mm 16 7 8 F2GP 22 C 1974 mm 77 3 4 626 mm 24 11 16 804 mm 31 3 4 F2...

Page 26: ...3 mm 15 16 54 mm 2 1 8 A B Mod le Largeur A Profondeur B Hauteur C F2GBP 12 C 1121 mm 44 1 8 626 mm 24 11 16 883 mm 34 3 4 F2GBP 14 C 1121 mm 44 1 8 626 mm 24 11 16 1635 mm 64 3 8 F2GBP 21 C 1974 mm 7...

Page 27: ...et du type d installation Installation des mod les mont s sur un comptoir Installation des mod les mont s au sol Installation des mod les encastr s Installation des mod les mont s sur un comptoir 1 P...

Page 28: ...mensions de la d coupe du mur 2 Retirez les vis des panneaux d acc s situ s en haut et en bas de chaque colonne de casiers c t client puis retirez ces panneaux 3 Soulevez l appareil et placez le avec...

Page 29: ...es de l appareil deviennent chaudes Toucher ces zones de l appareil avec pr caution 2 Pour les casiers dont le mode CHAUFF est activ Laissez aux casiers chauff s 30 minutes pour atteindre leur temp ra...

Page 30: ...ur d verrouiller un casier et en retirer de la nourriture c t client Les grandes lignes de cette proc dure doivent tre fournies au client 1 Sur l cran Commandes pr tes appuyez sur le nom sous lequel l...

Page 31: ...ne ic ne n appara tra c t du casier sur l cran de s lection des casiers 5 Appuyez sur pour revenir l cran de s lection des casiers Modifier le r glage chauff temp rature ambiante de tous les casiers 1...

Page 32: ...1 Sur l cran de s lection des casiers appuyez sur pour acc der aux param tres du syst me 2 Saisissez le code d acc s et appuyez sur ENTER entr e pour acc der l cran des param tres du syst me Le code...

Page 33: ...l dans la prise USB Le dossier du logiciel doit se trouver dans le dossier racine de la cl USB Le logiciel se met automatiquement jour lorsque la cl USB est ins r e Prise USB Panneau de commande cran...

Page 34: ...dans lesquels elles sont utilis es Certaines pi ces de rechange g n riques ou de second march ne pr sentent pas les caract ristiques leur permettant de fonctionner sans danger dans la mat riel Hatco C...

Page 35: ...l appareil en basculant l interrupteur d alimentation sur arr t puis nouveau sur marche Si le probl me persiste contactez une agence de service apr s vente agr e ou Hatco pour obtenir de l aide GUIDE...

Page 36: ...ode QR Utilisez les formats de donn es suivants lors de la cr ation d un code QR en fonction du type de code cr er Format de donn es pour le placement d une commande par l op rateur ORDER CREATE ORDER...

Page 37: ...c t client l aide du scanner de code QR Les grandes lignes de cette proc dure doivent tre fournies au client 1 Sur l cran Commandes pr tes scannez le code QR Si le nom du client ne figure pas sur la...

Page 38: ...la tablette circulaire 3 Ins rez la tablette lat rale sur les supports de la tablette circulaire Tablette lat rale Support de la tablette lat rale Installation de la tablette lat rale 4 Fixez la tabl...

Page 39: ...enveloppe m tallique l ments de pr sentation du r chaud enveloppe m tallique air chauffant l ments des armoires de stockage enveloppe m tallique air chauffant l ments de puits chauffants s ries HW HWB...

Page 40: ...ire Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 7...

Reviews: