INSTALLATION
Connecting the Components
Use the following procedure as a guideline for making
the connections between the components of the remote
refrigerated well system. These connections must be made by
trained and qualified installers and must comply with all local
plumbing and electrical codes. Refer to the SPECIFICATIONS
section and the wiring diagram included with the unit for details
regarding the plumbing and electrical connections.
1. Connect the liquid and suction refrigerant lines between the
condensing unit, the TXV valve, and the refrigerated well
evaporator coil. Refer to the appropriate illustration below
and the SPECIFICATIONS section for connection details.
NOTE: The maximum refrigerant line length between the
condensing unit and the evaporator coil is 50 feet (15 m).
NOTE: For refrigerant line connections, use a self-fluxing
brazing compound (example = Sil-Fos 5
®
) at a brazing
temperature range of 1300–1500°F (704–816°C).
Liquid
Connection
(1/4″ O.D. tube)
Liquid Connection
(3/8″ O.D. tube)
Condensing
Unit
Well
TXV Valve
Suction Connection
(3/8″ O.D. tube)
TXV Bulb
Fasten TXV bulb to
the suction side of
evaporator coil here.
Suction Connection
(3/8″ O.D. tube)
Suction Connection
(3/8″ O.D. tube)
CWBR Model Refrigerant Connections
Liquid Connection
(3/8″ O.D. tube)
Well
TXV Valve
Suction Connection
(3/8″ O.D. tube)
Suction Connection
(3/8″ O.D. tube)
Solenoid Valve
From
Condensin
g
Unit
To Conde
nsing
Unit
CWBX Model Refrigerant Connections
2. Have a qualified electrician make the appropriate electrical
connections to the Control Box. Refer to the wiring diagram
for details.
For CWBR and CWBR-S Models:
Condensing Unit
Power Input
a. Connect the on-site power
supply through the power
input knockout to the
POWER IN terminal block.
b. Connect power from the
POWER OUT terminal block,
through the power output
knockout, to the power input
on the condensing unit.
c. Connect the temperature
probe wire connector from
the well to the probe wire connector from the digital
temperature controller.
Power Input
Power Output
(to condensing unit on
CWBR Models or solenoid
valve on CWBX Models)
Temperature Probe
Wire Inlet
Terminal Blocks
Digital Temperature
Controller
Access Cover
Control Box Connections