3. INSTRUCTIONS FOR INSTALLATION
3.1. Prior to Installation
Prior to installing the heater, read all the instructions
for installation (figure 7), as well as checking the fol-
lowing points:
•
The heater volume should be suitable for the
sauna room volume. Table 2 shows the mini-
mum and maximum volumes for each heater
output. A precondition for the given values is that
the sauna room is well heatinsulated. Walls and
ceiling are covered with wood panel.
•
Check that supply voltage and amperages are
available for the heater.
•
The breakers and the connection cables con-
form with valid regulations and their dimen-
sions are in accordance with table 3.
•
The location is suitable for the heater
(
3.2.).
•
»
3.7.
Resetting the Overheat Protectors
Heater
Output
Dimensions (X/Y/Z)
Stones
Sauna room
Width/Depth/Height Weight
Cubic vol.
Floor Area Height
kW
inch
mm
lb/kg
max.
lb/kg
2.3.!
min.
CuFt/m³
max.
CuFt/m³
min
sqft
max
sqft
min.
inch/
mm
HSWS6U1B
6.0
17 / 10,2 / 27,6
430 / 260 / 700
32 /
14,3
44 /
20
177 /
5
294 /
8
28
47
75 /
1900
HSWS6U3B
HSW6U1B
HSW6U3B
HSWS8U1B
8.0
17 / 10,2 / 27,6
430 / 260 / 700
32,5 /
14,6
44 /
20
177/
5
431 /
12
28
69
75 /
1900
HSWS8U3B
HSW8U1B
HSW8U3B
Table 2. Installation details of the heater
Note! Only one electrical heater may be installed
in the sauna room. The heater should be installed
so that the warning texts can be read without
difficulty after the installation.
3.2. Place and Safety Distances
The minimum safety distances are described in
figure 3 and 4.
•
It is absolutely necessary to install the heater
according to these values. Neglecting them
causes a risk of fire.
•
Hot pieces of stone can damage floor coverings
and cause a risk of fire.
The floor coverings of
the installation place should be heat-resistant.
X
Z
Y
C
D
A
B
C
D
2.95” /
75 mm
9.84” /
250 mm
3.15”/
80 mm
44.1”/
1120 mm
Figure 4. Minimun safety distances (all heater models).
Seal tight conduit 90ºC wire