Item
number
Heating rods
CP-RBC-090
6 x SCA150 (1-028-518)
CP-RBC-105
3 x SCA150 (1-028-518) / 3 x SCA200 (1-028-503)
Instructions for installation and use
p. 24/26
10. Technical data
For the dimensions of the Concept R combi, refer to
Fig. 6
.
Item
number
Power
rating of
the heating
system
[kW]
Power
rating of
the evapo-
rator [kW]
Cabin
volume
[m
3
]
Minimum size of
ventilation
opening [mm]
CP-RCB-090
9.0
2.5
9 – 14
350 x 50
CP-RCB-105
10.5
2.5
10 – 15
350 x 60
Item
number
Weight with-
out stones
[kg]
Stone
weight
[kg]
Fuse [A]
Supply
voltage
CP-RCB-090
34
approx.
25
3 x 16
400 VAC 3N~
50/60 Hz
230 VAC 1N~
50/60 Hz
CP-RCB-105
34
approx.
25
3 x 16
400 VAC 3N~
50/60 Hz
230 VAC 1N~
50/60 Hz