8
Connecting the Star Wheels to the DCP
Locate the moisture harness (006-4640E2). Remove the
four pan head screws on each star wheel and loosen the
grommet. Insert the eye loop of the wire into the star wheel
block and install on the end of the swivel. Leave a loop in
the wire to allow the star wheel cover space to be
reinstalled. Tighten the swivel nut, followed by the grommet,
and finally install and tighten the four screws. The picture to
the right shows the star wheel block open with the wire
looped and attached to the swivel. Once both wheels are
complete route the harness towards the DCP on the back
right twine box. Be sure to mount and secure all harnesses
away from hydraulic lines and moving parts.
Connecting the Harnesses to the DCP
1. Install the green capped terminating resistor (006-5650Z) to the Dual Channel Processor (DCP).
2. Route the communication harness (006-6650VC) from the baler to the DCP. Attach the harness to the
whip harness coming off the base of the DCP. Secure harness from DCP to baler communication port.
3.
Install the baler’s black terminating resistor to the open end of the communication harness
(006-6650VC) next to the DCP.
4. Install the moisture harness (006-4640E2) into the DCP at the port marked Moisture Sensor. Secure
harness from DCP to star wheels.
Terminating resistor
006-5650Z
DCP
006-6671LS
Moisture harness
006-4640E2
Star wheels
006-4641
Baler Connection
Baler’s Black
Terminating Resistor
Comm. Harness
006-6650VC