4
INSTALLATION OF PIP INTERFACE CONTROL BOX
Installation of PIP Interface Control & Harness
The PIP Interface Controller (PIC) (006-5676) will mount next to the AGCO Bale Weighing
Controller. The AGCO Bale Weighing Controller will be located inside the right fender. Mark and
drill four 5/16 holes next to the bale scale and attach with four 1/4 x 1 “bolts and flange nuts.
Disconnect the harness plug shown above (figure 1). Connect the AGCO interface cable (006-
0890A) in the open port. Connect the AGCO scale harness plug into the other connection on the
AGCO interface cable. Connect the last connection into the PIC.
Locate a green terminating resistor (006-5650Z) on the Harvest Tec Precision Information Processor
(006-5671LS), Pump Controller (006-5672), or Tagger Control (006-5673). The terminating resistor
will be at different locations depending on the options installed. Remove the resistor. Connect one
end of the communication harness, found in the 890A kit (006-5650F) to the PIP Interface Control
box and the other connect to the open port were the terminating resistor was removed from.
Figure 1