background image

 

Microwave Sensor Installation 601A, 700MWM 

(continued)

 

 

In the eight 

locations indicated by the marks, drill 3/8” (10mm) diameter holes for the mounting bolts. Cut the 

rectangular area out using a grinder with cutoff wheel, reciprocating saw, or plasma cutter. Final results should 
look similar to the picture (figure 5). Test the fitment by placing the plastic filler plate (001-2600FP) in the 
rectangular hole. If the filler plate extrusion does not fully fit in the cutout, modify the cutout until the flanges of 
the filler plate fit flush against the outside of the PCC (figure 6). 

  

 

      

 

 

Install eight bolts 

5/16”x 1” BHCS from the inside of the pre-compression chamber through the side of the PCC 

and the plastic filler plate (001-2600FP). 

Secure the top two bolts and bottom two bolts with 5/16” flanged nuts. 

Place a mounting bracket over each of the two bolts on the sides of the filler plate and secure with 5/16” 
flanged nuts (figure 7).  
 
The right hand side mounting brackets (001-2600) should be aligned parallel with the long edges of the filler 
plate. Locate the sensor that says RX on the gray connector and mount it to the brackets using four 5/16-

3/4” 

bolts and flanged nuts (figure 8). The grey connector should be pointing down toward the ground. 

 

      

 

 
 
 

Repeat the procedure on the left side of the PCC for marking the locations, drilling and cutting, and mounting. 
The sensor labeled TX

 

on the gray connector needs to be mounted on the left hand side with the connector 

towards the ground.   

 
 
 
 
 
 
 

 

Figure 5 

Figure 6 

Figure 7 

Figure 8 

Summary of Contents for 601A

Page 1: ...1 601A 700 701 17 INST Imp Metric 6 22 Installation Manual Model 601A 700 701 Microwave Moisture Bale Chute System Pre Compression Chamber System Forage Harvester...

Page 2: ...application preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directiv...

Page 3: ...owave Sensor Installation 601A 700MWM 5 7 Microwave Sensor Installation 701MWM 8 Wiring Diagram 601A 9 Wiring Diagram 700MWM 10 Wiring Diagram 701MWM 11 Pin Outs 12 14 Common Questions 15 Troubleshoot...

Page 4: ...the back of the manual Right and Left sides are determined by facing in the direction of forward travel System Requirements The Baler Processor must have Version 3 3 or higher C1000 monitor must have...

Page 5: ...the slots on the side sheet figure 2 Clamp the template in place and use a marker or paint pen to mark the location for the eight holes that will need to be drilled and also mark the rectangular area...

Page 6: ...r through the side of the PCC and the plastic filler plate 001 2600FP Secure the top two bolts and bottom two bolts with 5 16 flanged nuts Place a mounting bracket over each of the two bolts on the si...

Page 7: ...at is labeled TX Route this wire behind the PCC in an area where it will not be pinched or snagged Locate the bearing on each side of the PCC figure 11 It works well to route the wire across to the ot...

Page 8: ...50MWL in the kit Start by locating the connector with the white heat shrink label marked RX Connect this connector to the sensor mounted on the right side chute 006 4641MRX If connecting to a moisture...

Page 9: ...re 006 5650K to a keyed power source 7 Connect the end to the Communication Harness 006 6650TM E to the Bluetooth Receiver 8 Connect the orange keyed power wire 006 5650K to a keyed power source on th...

Page 10: ...6672B to the Communication Harness 006 6650TM 7 Connect the Pre Compression Harness 006 6650MW into the Pump Controller port on the DCP 8 Connect Microwave Sensors 006 4641MTX 006 4641MRX to the Pre C...

Page 11: ...the Communication Harness 006 6650TM E 7 Connect the Chute Wire Harness 006 6650MWL into the Pump Controller port on the DCP 8 Connect Microwave Sensors 006 4641MTX 006 4641MRX to the Chute Wire Harne...

Page 12: ...an Hi Pin 7 Orange Can1 Hi Pin 8 Black Ground from BLE Pin 9 Black Ground from DCP Pin 10 Blue Can1 Low Bluetooth Receiver on Harness 006 6650TM E Pin 1 Red 12V Power from DCP Pin 2 Black Ground from...

Page 13: ...from tractor Pin 2 Black Ground from tractor Pin 3 Orange Keyed power Star Wheel and Bale Rate Sensor Connector on DCP Pin 1 Blue 12V Power Pin 2 Orange Ground Pin 3 Black Signal for sensor 1 Pin 4 Wh...

Page 14: ...re Harness 006 6650MW 006 6650MWL Pin 1 Red Power Pin 2 Black Ground Pin 3 N A Not Used Pin 4 Brown Signal Microwave Moisture Harness 006 6650MW 006 6650MWL RX Pin 1 Black Ground Pin 2 Red Power Pin 3...

Page 15: ...erformed A zero adjust should be performed on initial installation It is also recommended during a zero adjust calibration at the beginning of each season 10 When reading moisture with microwave senso...

Page 16: ...ltage should be constant between 12 and 14 volts 3 Install voltage surge protection on tractors alternator Terminal reads under or over power 1 Verify with multi meter actual voltage Voltage range sho...

Page 17: ...et 001 2600 4 2 Microwave TX Sensor 006 4641MTX 1 3 MWM Filter Plate 006 2600FP 2 4 MWM Pre Compression Harness 006 6650MW 1 5 Microwave RX Sensor 006 4641MRX 1 6 End of Bale Bracket Stuffer Bracket 0...

Page 18: ...4641MTX 1 3 End of Bale Extension Harness 20 006 7400MXT 1 4 MWM Pre Compression Harness 006 6650MWL 1 5 Microwave RX Sensor 006 4641MRX 1 6 End of Bale Bracket Stuffer Bracket 001 4648SS 1 7 End of B...

Page 19: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Page 20: ...20 HARVEST TEC LLC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Reviews: