Common Questions  

 

1.  How do I turn the system on/off? 

Turn the key in the tractor to the ON position. The ISOBUS Monitor will turn on, and the baler, on 600RB 
working screen tabs, will be viewable. Turn the system off by turning the tractor key OFF.   

 

2.  How to get in the LBS/TON, MC%, and TONS/HR menus?   

In the Main Menu press the SETUP MODE key.  From this screen you can change your alarm settings and 
bale rate settings.  See SETUP INSTRUCTIONS in the Operations Manual for a detailed explanation of 
this process. 

 

3. 

The moisture content displays “LO” or “HI” all the time.   

When the moisture content display does not change frequently while baling, there is likely a faulty moisture 
disc connection. Check all  wires and connectors to see if there is a continuity or grounding problem.   

 

4.  Should the battery connections be removed before jump starting or charging a battery? 

Yes. Anytime the tractor will have voltage going up rapidly the connections should be removed. 

 

5.  What is the moisture range of the moisture discs? 

The Moisture discs will read moisture levels from 7% up to 60%.  

 

6.  Can dielectric grease be used when connecting harnesses? 

Yes. Using dielectric grease will assist with good harness connections through the system. 

 

 

7. 

What do the lights on the 030-6672B indicate?

 

      

 Blinking Lights 

– System is waiting for the processor to connect, which could take up to 35 seconds. 

 

Red Light

 

– The Bluetooth receiver has power. 

Green Light

 

– When the proper active connection is 

selected in the Hay App menu, the green light will indicate connection with the iPad.

 

 

Troubleshooting 

 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

Moisture reading errors (high or low) 

1.  Wire disconnected or bad 
connection w/ moisture disc-DCP 

1. Reconnect wire. 

 

2.  Low power supply to DCP 

2. Check voltage at box. Min of 12V 

 

3.  Wet hay over 60% moisture 

 

 

4.  Ground contact with one or both 
moisture discs and BMP. 

4. Reconnect. 

 

5.  Short in wire DCP-disc 

5. Replace wire. 

 

6.  Check with hand tester 

6. Contact Harvest Tec if no change 

Moisture readings erratic. 

1.  Test bales with hand tester to 
verify that cab monitor has variance 

 

 

2.  Check all wiring connections for 
corrosion or poor contact. 

2. Apply dielectric grease to all 
connections.   

 

3.  Check power supply at tractor.  
Voltage should be between 12-14V 

3.  Install voltage surge protection on 
tractors alternator.   

Terminal reads under or over power. 

1.  Verify with multi-meter actual 
voltage. Voltage range should be 
between 12-14 volts. 

1. Clean connections and make sure 
applicator is hooked to battery.  

Bale rate displays zero. 

1.  Bale rate timer sensor error 
2.  Short in cable or sensor 

1. Check, clean, tighten connections 
2. Replace cable, Replace sensor. 

Display will not power up. 

1.  Connection broke between the 
display and the DCP. 
2.  Short in display cable. 

1. Check, clean, tighten connections 
2.  Replace cable. 

Bluetooth Receiver lights will not 
illuminate 

1.  Bluetooth receiver not 

connected 

2.  Harness disconnected, low pwr 

1.  Check connections and voltage. 

Minimum 12.5V needed. 

 

 

Blinking Lights 

– System is waiting for the processor to connect, which could 

take up to 35 seconds.  

Red Light

 

– The Bluetooth receiver has power 

Green Light

 

– When the proper active connection is selected in the Hay App 

menu, the green light will indicate connection with the iPad.  

Summary of Contents for 600RB

Page 1: ...Installation Manual Model 600RBC Moisture Sensor Kit for Roll Belt Round Balers Forage Harvester 600RBC 16 INST Imp Metric 5 18...

Page 2: ...preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2004 108...

Page 3: ...l Channel Processor DCP 5 Installation of Moisture Sensor Pads 6 7 Installation of Bale Rate Timer Sensor 7 Wiring Diagram 8 Pin Outs 9 10 Common Questions 11 Troubleshooting 11 Parts Breakdown 12 15...

Page 4: ...sture Monitor kit includes the following parts Dual Channel Processor DCP Moisture Sensors Harnesses Bluetooth receiver and Miscellaneous Hardware For your convenience a parts break down for the 600RB...

Page 5: ...nting bolts on support bar of right side of baler Figure 1 2 Install DCP mounting bracket 001 4703XI as shown Figure 2 3 Install DCP onto mounting bracket 001 4703XI and secure Figure 3 4 Cover with D...

Page 6: ...ount that protrudes into the chamber Remove and cut off excess material Repeat for other side 5 Using 4 carriage bolt slide the parts on in following order metal disc 001 4641HX plastic isolator 006 4...

Page 7: ...e hinge to mount the bracket Check for clearance with hydraulic cylinders before mounting the bracket The bracket should be mounted to the front side of the hinge point with the sensor aligned over th...

Page 8: ...product used D Connect the black ground wire to frame of tractor or negative side of battery 12 volt E Connect the baler power and communication harness 006 6650LS to the power port on the DCP and to...

Page 9: ...Pin 6 Yellow HT Can Hi Pin 7 Orange Can1 Hi Pin 8 Black Ground from TSD Pin 9 Black Ground from DCP Pin 10 Blue Can1 Low Bluetooth Receiver Harness 006 6650TM E at TSD Pin 1 Red 12V Power from DCP Pin...

Page 10: ...nd Bale Rate Sensor connector on DCP Pin 1 Blue 12V Power Pin 2 Orange Ground Pin 3 Black Signal for sensor 1 Pin 4 White Signal for sensor 2 Pin 5 N A Pin 6 N A Pin 7 N A Pin 8 Violet Star wheel inpu...

Page 11: ...cate connection with the iPad Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Moisture reading errors high or low 1 Wire disconnected or bad connection w moisture disc DCP 1 Reconnect wire 2 Low power...

Page 12: ...01 5650X 1 4 DCP Main Control LS 600 AUTO 006 6671RB 1 5 DCP Baler Harness 15 FT 006 6650LS 1 6 DCP Tractor Harness 006 6650TM 1 7 Dust Plugs 006 5651PLUGS 1 8 Round Baler End of Bale Bracket 001 4648...

Page 13: ...B Moisture Disk 006 4641HX 2 3 1 2 JAM Nut Misc Hardware 4 4 1 2 Lock Misc Hardware 4 5 1 2 D Washer Misc Hardware 6 6 1 2 x 4 Bolt Misc Hardware 2 7 Sensor Bushing 006 4641G 2 8 Sensor Isolator 006 4...

Page 14: ...ing plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole in the preferred mo...

Page 15: ...emove the round locking plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole...

Page 16: ...16 Notes...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Page 20: ...20 HARVEST TEC INC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Reviews: