background image

 
 
 

 

 

Installation Manual 

                       Model 600RBC

 

Moisture Sensor Kit for Roll-Belt Round Balers  

 

 

Forage Harvester

 

600RBC-16-INST-Imp&Metric 

5/18 

 

 

Summary of Contents for 600RB

Page 1: ...Installation Manual Model 600RBC Moisture Sensor Kit for Roll Belt Round Balers Forage Harvester 600RBC 16 INST Imp Metric 5 18...

Page 2: ...preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 2004 108...

Page 3: ...l Channel Processor DCP 5 Installation of Moisture Sensor Pads 6 7 Installation of Bale Rate Timer Sensor 7 Wiring Diagram 8 Pin Outs 9 10 Common Questions 11 Troubleshooting 11 Parts Breakdown 12 15...

Page 4: ...sture Monitor kit includes the following parts Dual Channel Processor DCP Moisture Sensors Harnesses Bluetooth receiver and Miscellaneous Hardware For your convenience a parts break down for the 600RB...

Page 5: ...nting bolts on support bar of right side of baler Figure 1 2 Install DCP mounting bracket 001 4703XI as shown Figure 2 3 Install DCP onto mounting bracket 001 4703XI and secure Figure 3 4 Cover with D...

Page 6: ...ount that protrudes into the chamber Remove and cut off excess material Repeat for other side 5 Using 4 carriage bolt slide the parts on in following order metal disc 001 4641HX plastic isolator 006 4...

Page 7: ...e hinge to mount the bracket Check for clearance with hydraulic cylinders before mounting the bracket The bracket should be mounted to the front side of the hinge point with the sensor aligned over th...

Page 8: ...product used D Connect the black ground wire to frame of tractor or negative side of battery 12 volt E Connect the baler power and communication harness 006 6650LS to the power port on the DCP and to...

Page 9: ...Pin 6 Yellow HT Can Hi Pin 7 Orange Can1 Hi Pin 8 Black Ground from TSD Pin 9 Black Ground from DCP Pin 10 Blue Can1 Low Bluetooth Receiver Harness 006 6650TM E at TSD Pin 1 Red 12V Power from DCP Pin...

Page 10: ...nd Bale Rate Sensor connector on DCP Pin 1 Blue 12V Power Pin 2 Orange Ground Pin 3 Black Signal for sensor 1 Pin 4 White Signal for sensor 2 Pin 5 N A Pin 6 N A Pin 7 N A Pin 8 Violet Star wheel inpu...

Page 11: ...cate connection with the iPad Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Moisture reading errors high or low 1 Wire disconnected or bad connection w moisture disc DCP 1 Reconnect wire 2 Low power...

Page 12: ...01 5650X 1 4 DCP Main Control LS 600 AUTO 006 6671RB 1 5 DCP Baler Harness 15 FT 006 6650LS 1 6 DCP Tractor Harness 006 6650TM 1 7 Dust Plugs 006 5651PLUGS 1 8 Round Baler End of Bale Bracket 001 4648...

Page 13: ...B Moisture Disk 006 4641HX 2 3 1 2 JAM Nut Misc Hardware 4 4 1 2 Lock Misc Hardware 4 5 1 2 D Washer Misc Hardware 6 6 1 2 x 4 Bolt Misc Hardware 2 7 Sensor Bushing 006 4641G 2 8 Sensor Isolator 006 4...

Page 14: ...ing plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole in the preferred mo...

Page 15: ...emove the round locking plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole...

Page 16: ...16 Notes...

Page 17: ...17 Notes...

Page 18: ...18 Notes...

Page 19: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Page 20: ...20 HARVEST TEC INC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...