![Harvest TEC 445Z Installation Manual Download Page 9](http://html1.mh-extra.com/html/harvest-tec/445z/445z_installation-manual_2103712009.webp)
9
Installation of Controls and Routing the Wire Harnesses
A. Locate the control in an area that allows operation for adjusting or turning the controls while operating
the baler.
B. Route the wire to the starter solenoid on all 12V tractors. Connect the green lead marked
+
to the hot
terminal on the starter. Connect the black lead to a good ground.
Do not reverse the leads.
Be sure
to use a voltmeter to verify that you do have 12 volts running to the box.
Note:
For tractors with 24v starters, connect the power leads to the
tractor’s right-hand battery. Do not
connect the leads to the starter. Connect the lead to the positive battery terminal and the lead
marked- to the negative on the battery. Wiring connections to the battery normally results in corrosion;
terminal coating is recommended.
C. Attach the wire from the pump to the battery
D. Run wire with molded black plug to back of tractor
E. Run wire from pump up drawbar and connect it to the mating plug from the control box. Secure wire to
baler with supplied cable ties.
Caution:
Do not run a pump or use an electronic control box directly off a battery charger. For stationary use,
the applicator can be connected to a new battery and the battery connected to a charge