SPECIFICATIONS
TRANSMITTER SECTION
a. RF Output Power
b. Freq. Deviation (@1 KHz)
c. Audio Freq. Response
4 watts (MPT-1320)
±2.5 KHz max.
+2
-5
at 0.3-3.0 Khz pre-emphasise
less than 50nw
dB per 6dB/OCT
d. Spurious Emission
80 - 86 Mhz
87.5 -118 Mhz
135-136 Mhz
174-230 Mhz
470 - 862 Mhz
Other Freq. Less than 0.25uW
e. Adjacent Channel Power less than 10uW
POWER SUPPLY
AC OPERATION
For your own safety read following instruction carefully before attempting to connect
this unit to the mains.
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code:
Green-and-yellow
: Earth
Blue : Neutral
Brown : Live
As the colours of the wires in the mains lead of this apparatus may not correspond with
the coloured markings identifying the terminals in your plug proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the
plug which is marked by the letter E or by the safety earth symbol or coloured green or
green-and-yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
If a 13A plug is used, fit a 3A Fuse. If any other plug is used, protect with a 5A fuse in
the plug, adaptor, or at the distribution board.
CAUTION:
TO PREVENT ELECTRIC SHOCK DISCONNECT FROM THE MAINS BEFORE
REMOVING COVER. NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL
SAFETY PRECAUTION:
THIS EQUIPMENT MUST BE DISCONNECTED FROM THE MAINS WHEN NOT IN USE.
*DO NOT ALLOW THIS UNIT TO BE EXPOSED TO RAIN OR MOISTURE.
WARNING:
THIS APPARATUS MUST BE EARTHED.
- 7 -