1-14
888-2621-001
12/5/07
WARNING: Disconnect primary power prior to servicing.
Section I Operator Guide
Z3-48HD+
Table 1-5 ZD32 System Controller: FM Only Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
20kW of system forward power
R37
TP3
0.075 Volts
800 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 5kW
R78
Table 1-6 Z3-48HD+ System Controller: FM+HD Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
21kW of system forward power
R37
TP3
0.075 Volts
840 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 4.67kW
R78
Table 1-7 Z3-48HD+ System Controller: HD Only Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
10.5kW of system forward power
R37
TP3
0.075 Volts
420 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 2.33kW
R78
Table 1-8 Z3-48HD+ System Controller: FM Only Mode
TEST
POINT
TARGET
VOLTAGE
SET UP CONDITION
SAMPLE
CAL
TP2
0.275 Volts
30kW of system forward power
R37
TP3
0.075 Volts
1200 Watts of simulated reflected power
R45
TP4
0.275 Volts
100% of reject power; 6.67kW
R78
Summary of Contents for Z3-48HD+
Page 4: ...MRH 2 888 2621 001 12 5 07 WARNING Disconnect primary power prior to servicing ...
Page 6: ...12 5 07 888 2621 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 7: ...12 5 07 888 2621 001 vii WARNING Disconnect primary power prior to servicing ...
Page 9: ...12 5 07 888 2621 001 ix WARNING Disconnect primary power prior to servicing ...
Page 12: ...2 888 2508 001 WARNING Disconnect primary power prior to servicing Table of Contents ...