Returns And Exchanges
Damaged or undamaged equipment should not be returned unless a Return
Authorization is issued. When communicating with Harris Corporation, Broadcast
Division, specify the order number or invoice number. Include complete details
regarding circumstances and reasons for return in the request. Custom or special order
equipment is not returnable. In instances where return or exchange of equipment is at
the request or convenience of the customer, a restocking fee will be charged. Special
shipping instructions and coding will be provided to insure proper handling. All returns
will be sent freight prepaid and properly insured by the customer.
1.2.2
Unpacking
Carefully unpack the transmitter and save all packing material. Inspect thoroughly for
any damage incurred in shipment. Retain all PACKING CHECK LISTS to help locate
and identify any components or assemblies removed for shipping. Remove any
shipping supports, and straps prior to initial turn on.
Before cabinet placement takes place, it is important to determine which cabinet is
transmitter C (left side as viewed from the front), transmitter A (middle), and
transmitter B (right side). This can be determined by looking at the tags on the front of
the transmitter or matching serial numbers of the cabinet to the provided test data. The
serial numbers of the cabinets can be found on the left side wall inside the module
compartment. A typical system will have the FlexStar HDx-FM Exciter(s) in the left
cabinet.
1.2.3
Installation
NOTE:
It is important to have and study all documentation of all units involved in a Z3-
48HD+ system prior to begining installation of this comlex system.
The cabinets may be mounted together using four Cabinet Brackets and hardware
provided with the system. The Cabinet Brackets mount between the transmitters on top
using the 3/8" hardware into threads found near the front and back of any two cabinets.
1/2" hardware is provided to bolt two cabinets together near the bottom. These holes
may be accessed inside the power supply compartments of all three cabinets. The
supply may need to be pushed forward a few inches in order to gain access to the back
hole.
Summary of Contents for Z3-48HD+
Page 4: ...MRH 2 888 2621 001 12 5 07 WARNING Disconnect primary power prior to servicing ...
Page 6: ...12 5 07 888 2621 001 MRH 1 WARNING Disconnect primary power prior to servicing ...
Page 7: ...12 5 07 888 2621 001 vii WARNING Disconnect primary power prior to servicing ...
Page 9: ...12 5 07 888 2621 001 ix WARNING Disconnect primary power prior to servicing ...
Page 12: ...2 888 2508 001 WARNING Disconnect primary power prior to servicing Table of Contents ...