![Harris TVS-D 660 Operator'S Manual Download Page 51](http://html1.mh-extra.com/html/harris/tvs-d-660/tvs-d-660_operators-manual_4032968051.webp)
MAINS(1) FAILURE
Indicates a mains break-down (mains 1)
MAINS(2) FAILURE
Indicates a mains break-down (mains 2)
MUTING ACTIVATED
Output of OFE is muted.
OCXO - BACKUPTIME
REACHED
Frequency out of guard interval because OCXO control
frequency is missing.
OCXO CTRL FREQUENCY
MISSING
1 pps and external reference frequency missing.
OCXO GUARD INTERVAL
PASSED
OCXO is now out of the
guard interval
OUTPUT FORCED MGC
SELECTED
Configuration was changed.
Reflection / Amplifier fault.
Check the antenna /
module. Change the gain.
OUTPUT OSC. TUNING
NEAR LIMIT
—-
Tune the AU.
OVERTEMPERATURE
Amplifier temperature is too
high
Check if the vents are not
blocked.
PA AGC DEVIATION
There is a power amplifier
automatic gain control
deviation .
Optimise the power of the
broadband amplifier till the
deviation is “0”.
POLY FUSE RESPONDED A short-circuit may be
present.
Switch installation off and
on again.
POWER RED. - WARNING
INDICATED
An external warning was
detected.
See warning handling in the
transmitter operating
manual
POWER REDUCED. -
REFL. LEVEL
Reflection level too high -
power was reduced.
See reflection handling in
the transmitter operating
manual.
RF OUT. LEVEL <
WARNING THRES.
The amplification was not
properly adjusted.
Increase the amplification in
the menu “OUTPUT UNIT”,
until the RF output level is
above the adjusted
threshold.
RF-BLOCKING ACTIVE
Signal line connected to
ground - no output power.
Check the installation.
SAFETYLOOP OPEN
Safety loop interrupted - no
output power.
Check the connector on the
rack door.
SOC BLANKINGLOOP
ACTIVE
STORAGE BATTERY LOW The storage battery level is
low.
This message may appear
in the event of a mains
break-down. After 2
minutes the transmitter will
be shut down.
TESTMODE ACTIVE
OFE is running in testmode Set Testmode OFF
Information
Message
Meaning
1 PPS of internal GPS missing
1 PPS signal absent
10 MHZ OSC. TEMPERATURE LOW
10 MHz oscillator is heating up.
AMPL. MODE SERVICE SELECTED
—-
AMPLIFIER MODE OFF SELECTED
—-
AMPL. MODE ON SELECTED
—-
COLD RESET DONE
A cold reset was performed.
Operator manual
TVS-D 660 LC-Display
3 - 5
Appendix
Summary of Contents for TVS-D 660
Page 1: ...Operator Manual TVS D 660 LC Display Version 2 1 Print November 2004 071571441 BN_5714E...
Page 5: ...Introduction Operator manual TVS D 660 LC Display 1 1 Introduction...
Page 9: ...Menu Operation Operator manual TVS D 660 LC Display 2 5 Menu Operation...
Page 10: ...Menu Tree Operator manual 2 6 TVS D 660 LC Display Menu Operation...
Page 30: ...REF LO UNIT Menu With GPS Without GPS Operator manual 2 26 TVS D 660 LC Display Menu Operation...
Page 47: ...Appendix Operator manual TVS D 660 LC Display 3 1 Appendix...