HMX6801
+
B2/C2 and HMX6801
+
B4/C4 Installation and Operation Manual
51
Chapter 3: Operation
0, 2
Y CRC Err Cnt
Clear
Clears the luminance CRC error
counter
•
No
• Yes
0, 3
C CRC Err Cnt
Clear
Clears the chrominance CRC error
counter
•
No
• Yes
0, 4
EDH Err Clr
Clears the EDH error counter
•
No
• Yes
0, 5
ADS Clean
Cleans the Ancillary Data Space
prior to audio embedding
•
No
• Yes
0, 6
Embedder Group
Select
1
Selects the audio groups to be
embedded
•
1 & 2
• 1 & 3
• 1 & 4
• 2 & 3
• 2 & 4
• 3 & 4
0, 7
Embedder 1
Mode
Selects the embedding mode for the
first embedder
• Off
• Append
• OverWrt
•
Auto
0, 8
Embedder 2
Mode
Selects the embedding mode for the
second embedder
• Off
• Append
• OverWrt
•
Auto
0, 9
Input Ch1A
Delay
Adjusts delay for input channel
AES 1A
0.0
to 1320.0 msec
0, A
Input Ch1B Delay Adjusts delay for input channel
AES 1B
0.0
to 1320.0 msec
0, B
Input Ch2A
Delay
Adjusts delay for input channel
AES 2A
0.0
to 1320.0 msec
0, C
Input Ch2B Delay Adjusts delay for input channel
AES 2B
0.0
to 1320.0 msec
Table 3-11.
Parameter Options - HMX6801
+
B4/C4
(Continued)
Bank, Rotary
Switch
Parameter
Name
Function
Options