![Harris Gates One 994 9202 002 Technical Manual Download Page 16](http://html1.mh-extra.com/html/harris/gates-one-994-9202-002/gates-one-994-9202-002_technical-manual_4046283016.webp)
POWER OUTPUT:
5000 watts (Rated). Six power levels adjustable between 500-5600 watts. Capable of
lower power PSA/PSSA operation.
RF FREQUENCY RANGE:
531 kHz through 1705 kHz. Supplied to one frequency as ordered.
CARRIER FREQUENCY STABILITY:
Crystal control oscillator meets FCC specifications. +/-4 Hz in typical operating
environment.
RF OUTPUT IMPEDANCE:
50 ohms unbalanced.
RF OUTPUT TUNING:
Integral network will match a VSWR of 1.5:1 to 1.0:1 at carrier.
RF OUTPUT TERMINAL:
7/8" EIA male/female flange connector.
CARRIER SHIFT:
Less than 1% at 100% modulation at 1000 Hz.
RF HARMONICS AND SPURIOUS EMIS-
SIONS:
Exceeds FCC and CCIR specifications.
OTHER EMISSIONS:
Meets FCC NRSC 2 when presented with audio signal conforming to NRSC 1
standard.
TYPE OF MODULATOR:
Patented Polyphase PDM.
AUDIO FREQUENCY RESPONSE:
+/-0.5 dB, from 20 to 10,000 Hz (with Bessel filter out).
AUDIO HARMONIC DISTORTION:
Less than 0.8% at 5000 watts, typically less than 1.5% at 1 kW, 20 to 10,000 Hz @
95% modulation.
AUDIO INTERMODULATION DISTORTION: Less than 1.0%, 60/7000 Hz 1:1. Less than 1.5%, 60/7000 Hz 4:1, SMPTE standards
at 5000 watts operation at 95% modulation.
SQUAREWAVE OVERSHOOT:
Less than 3.5% at 400 Hz.
SQUAREWAVE TILT:
Less than 3% at 20 Hz, 90% modulation.
Less than 1.5% at 40 Hz, 90% modulation.
NOISE (UNWEIGHTED):
Better than 60 dB below 100% modulation, 1000 Hz at 2500 watts to 5000 watts.
POSITIVE PEAK CAPABILITY:
Greater than 130% positive peak program modulation capability at 5600 watts.
INCIDENTAL QUADRATURE MODULA-
TION (IQM):
30 dB typical below 95% modulation of L+R channel at 1 kHz.
AUDIO INPUT:
Continuously adjustable from -10 to +10 dBm, transformer-less active 600 ohms input.
AC VOLTAGE INPUT:
197-251 VAC, 50/60 Hz, three phase or international 341 to 434 VAC. Compatible
with WYE or closed delta power sources. AC voltage variation: +5, -10% for full
performance. Single phase version accepts 197 to 251 VAC 50/60 Hz.
OVERALL EFFICIENCY:
Better than 65% at 5000W.
POWER CONSUMPTION:
At 5000 watts carrier, 7692 watts or less at 0% modulation, 11538 watts or less at
100% sine wave modulation, 9615 watts during typical programming.
MONITOR PROVISIONS:
Adjustable to 5 volts nominal RMS modulated output sample at 50 ohms for six power
levels from 500 watts to 5600 watts.
REMOTE CONTROL/MONITORING:
Self-contained interface for most remote control systems TTL compatible.
AMBIENT TEMPERATURE RANGE:
-10°C to +50°C AMSL (derate upper limit 2°C per 1000 feet altitude).
AMBIENT HUMIDITY RANGE:
To 95%, non condensing.
AIR FLOW:
500 CFM, (14.16 CMM).
HEAT GENERATED:
13790 BTU per hour at 5000 watts, 100% tone modulation.
ALTITUDE:
Up to 13,000 feet (4000 meters).
SIZE:
72"H X 28"W X 30"D (1830 mm X 712 mm X 762 mm).
WEIGHT:
(Unpacked) 500 lbs. (230 kg) - approximate. Domestic packed, 700 lbs. (320 kg) -
approximate. Export packed, 800 lbs. (370 kg) - approximate.
CUBAGE:
68.7 cubic feet (2 cubic meters) packed.
NOTE: ALL SPECIFICATIONS TAKEN WITH TRANSMITTER CONNECTED TO TEST LOAD. SPECIFICATIONS SUBJECT
TO CHANGE WITHOUT NOTICE.
Table 1-3. GATES FIVE Specifications
1-4
888-2314-001
Rev. T: Jan. 1996
WARNING: Disconnect primary power prior to servicing.
Summary of Contents for Gates One 994 9202 002
Page 4: ......
Page 6: ...iv 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Page 8: ...vi 888 2314 001 Rev X WARNING Disconnect primary power prior to servicing...
Page 28: ...2 12 888 2314 001 Rev AC 2 29 00 WARNING Disconnect primary power prior to servicing...
Page 76: ...C 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 82: ...E 4 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 88: ...F 6 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 96: ...H 2 888 2314 001 Rev AA 8 18 1999 WARNING Disconnect primary power prior to servicing...
Page 104: ...K 2 888 2314 001 Rev AE 03 05 2002 WARNING Disconnect primary power prior to servicing...
Page 108: ...L 2 888 2314 001 WARNING Disconnect primary power prior to servicing...