DHSD / DHSE6800
+
Installation and Operation Manual
25
Chapter 3: Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Setting Remotely Controlled Parameters
describes DHSD6800
+
parameters that are accessible
remotely;
describes DHSE6800
+
parameters that
are accessible remotely. See your CCS control software application
manual or online help for more information on setting and monitoring
these parameters remotely.
•
Default values are marked with an asterisk (*).
•
Parameters with the symbol [RO] are read-only. Read-only
parameter default values are not marked, as they report system
status indicators.
Table 3-2.
DHSD6800
+
Remotely Controlled Parameters
Name
Range
Description
Loss of signal switch
• 0 = Disable*
• 1 = Enable
Loss of signal (input 1) switching
enable, automatically switch both
output MUXs to select input 2
when input 1 has lost its input
signal
Output configuration
• 0=1×8*
• 1=1×4
Allows you to select if the card is
in dual 1×4 or 1×8 Input 1 routed to
all outputs
Signal present [RO]
• 0=No
• 1=Yes
Indicates if the input is present or
not
Input rate
• 0=HD
• 1=SD
Allows you to specify the input rate
as either HD or SD
Loss of input alarm
• 0=Disable*
• 1=Enable
Enables or disables the Loss of
Input alarm
Loss of lock alarm
• 0=Disable*
• 1=Enable
Enables or disables the Loss of
Lock alarm
Table 3-3.
DHSE6800
+
Remotely Controlled Parameters
Name
Range
Description
Loss of signal switch
• 0 = Disable*
• 1 = Enable
Loss of signal (input 1) switching
enable, automatically switch both
output MUXs to select input 2
when input 1 has lost its input
signal