![Harris DHSD6800+ Installation And Operation Manual Download Page 34](http://html1.mh-extra.com/html/harris/dhsd6800/dhsd6800_installation-and-operation-manual_4010847034.webp)
22
DHSD / DHSE6800
+
Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Local Control
Local Control Reclocking Mode
In the local control reclock setting operation mode, all of the settings’
data status information appears on the Leitch
+
Pilot Lite control screen;
however, you cannot change any setting in this mode via
+
Pilot Lite. To
control the reclocking setting mode via
+
Pilot Lite, set the jumper to the
remote control reclock setting operation mode.
For local control, P2/P3 is used to determine reclocking mode:
Note
Leitch recommends that you use
the available 6800
+
software
control options (serial / local or
Ethernet / remote) to aid in
viewing, setting, and confirming
parameter values.
Table 3-1.
P2
/
P3 Local Control Reclock Modes
Reclock Mode
Description
AUTO
(Default)
Automatically detects the rate; if no selection rate jumpers are selected, the selection will be
AUTO
143
Forces channel to lock to a 143 Mb / s signal
Set the jumper on the pin that allows the reclocker to handle 143 Mb / s data only
• If the 143 reclock mode is selected, the 143 Mb / s LED will turn on
• If the module can successfully lock to the input, the lock LED will turn on
• If reclocking is not successful, the lock LED will turn off and the un-reclocked data will
be present at the output
177
Forces channel to lock to a 177 Mb / s signal
Set the jumper on the pin that allows the reclocker to handle 177 Mb / s data only
• If the 177 reclock mode is selected, the 177 Mb / s LED will turn on
• If the module can successfully lock to the input, the lock LED will turn on
• If reclocking is not successful, the lock LED will turn off and the un-reclocked data will
be present at the output
270
Forces channel to lock to a 270 Mb / s signal
Set the jumper on the pin that allows the reclocker to handle 270 Mb / s data only
• If the 270 reclock mode is selected, the 270 Mb / s LED will turn on
• If the module can successfully lock to the input, the lock LED will turn on
• If reclocking is not successful, the lock LED will turn off and the un-reclocked data will
be present at the output
360
Forces channel to lock to a 360 Mb / s signal
Set the jumper on the pin that allows the reclocker to handle 360 Mb / s data only
• If the 360 reclock mode is selected, the 360 Mb / s LED will turn on
• If the module can successfully lock to the input, the lock LED will turn on
• If reclocking is not successful, the lock LED will turn off and the un-reclocked data will
be present at the output
Summary of Contents for DHSD6800+