AES-3981 Installation and Operation Manual
25
Chapter 3: Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Alarms
The AES-3981 provides a default list of 6 alarms. (
Table 3-2 on page 26
lists the major and minor alarms, and their descriptions.) You can
disable any alarm by modifying the
Alarms
parameters in the
Setup
section.
When you select
Alarms
, all of the active alarms are visible in the
display, below
Config
(Configurations). If no alarms are active, only
Config
appears.
Alarm Synchronization
Alarm synchronization is available for this module if your NEO frame
contains a 3901RES-E resource module that supports the feature. When
active, alarm synchronization ensures that the alarm configuration
settings of card-edge controls and the CCS control software and control
panels are consistent.
If the AES-3981 module is set for local control, the alarm settings will
appear the same at both the card edge and via CCS, but the settings can
only be changed using the card-edge controls. If the module is set for
remote control, the alarm settings can be changed via both the card edge
and CCS control software and control panels. Alarm configuration
settings undergo DejaView (state recovery) automatically. This means
that when a module is hot-swapped, the alarm configuration for the new
module is updated to the settings of the module that was previously in
that slot. See
“State Recovery Parameter Availability” on page 26
for
more information.
Identifying the Cause of an Alarm
To identify the reason for an alarm, select
Alarm
, scroll to an active
alarm, then press
Select
. A scrolling message that describes the cause of
the fault will appear on the VFD.
Enabling or Disabling an Alarm Parameter
To enable or disable an alarm parameter, follow these steps:
1. Select
Alarms
, then select
Config
, then press
Select
.
2. Select one of the alarm parameters, then press
Select
.
3. Press
Enabled
or
Disabled
.