background image

 
 

Harrie Leenders Haardkachels BV 

 

Manual Ysen, due to changes, October 2014. 

 

 
 

Regulations 

 

 

 

Safety

 

 

 

 

Glass is quite susceptible to breaking and broken glass is quite sharp. Take appropriate measures. 

 

For general safety, we refer to the VCA guidelines. 

 

Note: After installation, ensure there is no inflammable and/or explosion-hazardous material in or on 
the stove such as a spray can, packing material and the like. 

 
 
 
 

 

 

 

Safety 

distances 

 

 

Safety distance to flammable materials: 

 

Rear wall; 25cm. 

 Temperature at safety test; 65°C.

 

 

Side wall; 40cm. 

 Temperature at safety test; 77°C.

 

 
 
 
 
 
 
 
 

 

 

 

 

Specification

 

 

 

Nominal power = 9,9 kW 

 

Power range = 4-12 kW 

 

Flue gass mass flow = 8,1 g/s 

 

Appliance weight = 300 kg 

 

Minimum chimney draught = 12 Pa 

 

Flue gas temperature directly over the stove = 266 °C 

 
 

 

 

 

Service 

 

 

 

It is not permitted to make any changes or modifications to the appliance without the manufacturer’s 
prior authorization. 

 

Only use replacement parts reccomended by the manufacturer. 

 

Instructions, sizes and other service materials  are available on 

service.leenders.nl

 

 