Instructions

 

 

 

 

Installation 

 

 

 

All local regulations including those referring to national and European standards must be  

   observed when using the appliance. 

 

To ensure warranty the appliance has to be installed by a prorerly qualified technician in service of a 
Harrie Leenders Haardkachels dealer. See 

leenders.nl

 for a current list of addresses of recognised dealers 

or contact the manufacturer. 

 

The stove is susceptible to scratching. Handle with care.

 

 

The appliance is not suitable for a shared flue system.

 

 

The appliance must be installed on a floor having sufficient bearing capacity.

 

 

Ensure adequate access for cleaning the appliance, the flue-gas connection and the chimney.

 

 

After installation, check the draught by burning some kindling wood.

 

 

 

 

 

Use 

 

 

 

Ensure that there are no flammable materials in close vicinity to the stove. 

 

The appliance is only suitable to be fired with the door closed. 

 

 

Parts of the appliance and the surface in particular are hot when touched when the appliance is being 
used. Take appropriate measures. 

 

Use firewood abt. 25 cm long and abt. 7 cm thick. Place it flat on the bottom. Place no more than 3 logs in 
the stove at a time. Add wood to the stove when the fire is going down, after burning for about 1 hour. 

 

Do not use the appliance as a multi-burner. Do not use unsuitable fuels or any fuels not recommended 
and, especially, do not use any liquid fuels. 

 

Ensure there is sufficient ventilation/air supply in the room where the stove is installed. Air extractors such 
as a cooker hood may cause problems due to flue gases escaping from the stove into the room.

 

 

 

Maintenance 

 

 

 

Ensure maintenance of the appliance at regular intervals to be carried by a competent technician. 

 

Ensure that the flue-gas connection and the chimney are cleaned at regular intervals. 

 

Check to ensure that the chimney is still clear before lighting the stove again, when the appliance has not 
been used for a long time. 

 

If in spite of precautions having been taken, nevertheless a chimney fire should occur (a roaring noise in 
the chimney), proceed as follows: 

-

 

Immediately shut the air supply and the door of the stove.

 

-

 

Call the fire brigade.

 

 

-

 

Ventilate the house. 

-

 

Quickly extinguish the fire in the stove with sand or soda to prevent smoke from getting into your house. 

-

 

Never use water to extinguish the fire. 

-

 

After a fire, ensure that the chimney is first swept and inspected for any damage and leaks. 

 

 

 