Harrie Leenders HL2 Instructions for Installation, Use and Maintenance
17
Installation instructions
·
All local regulations including those referring to national and European standards
must be observed when installing the appliance.
·
Ensure there is sufficient ventilation / air supply in the room from which your stove
gets the combustion air. This is the room where the stove is installed if you do not
use a wall or stovebase airsupply system.
·
The stove is not suitable for a shared flue system.
·
Ensure adequate access for cleaning the appliance, the flue gas connection and the
chimney.
·
When installing the stove, take into account the minimum distances from the wall so
as to avoid any fire risk. The minimum distances (sizes in cm) are shown in the
figure below.
Specifications HL2
Nominal power of the stove is 6 kW.
Flue gas mass flow = 5.4 g/s
Appliance weight = 85 kg
Minimum chimney draught = 10.0 Pa
Flue gas temperature directly over the stove = 238 °C