Arm Bed
10
White wire attaches to the top inside manifold
coil.
Black wire attaches to the bottom outside
manifold coil.
Green wire attaches to the bottom inside
manifold coil.
Wiring Instructions/Corded Remote Arm
Bed
•
See parts page 1.6 for more detail.
•
Blue wire attaches to the top outside
manifold coil. This is the “OUT” on the
arm wired remote.
•
White wire attaches to the top inside
manifold coil. This is the “IN” on the
arm wired remote.
•
Black wire attaches to the bottom
outside manifold coil wire mates. This
is the “DOWN” on the arm wired
remote.
•
Green wire attaches to the bottom
inside manifold coil. This is the “UP”
on the arm wired remote.
•
Red wire attaches to the input on the
motor start solenoid along with the red
battery cable.
•
Orange wire attaches to the actuator
(small post) on the motor start
solenoid.
•
The black battery cable connects to
bottom of pump block. Note: Scratch
surface paint on box for proper
grounding. Some trucks may
require ground wire run all the way to
the battery to establish grounding.
Note: When wiring, inside coils are facing
back of box. Outside coils are facing tool
box lid.
Blue wire attaches to the top outside manifold
coil.
Corded/Wireless Remotes