Chapter 3 User Interface Options
NETWatch Site Controller
© 2009 Harmonic Inc.
20
SPL 7110-Exx, Version 1.0, Rev A
3.1.2
Transmitter Setup
The Transmitter Setup menu allows you to:
■
Run the Autosetup routine
■
Select Manual Gain Control (MGC) or Automatic Gain Control (AGC) mode of operation
■
Enter the transmission distance
3.1.3
Transmitter Adjustments
The Transmitter Adjustments menu allows you to:
■
Adjust and optimize the RF pad settings
■
Set the RF input low level alarm limit
■
Restore all transmitter parameters to the original factory settings
3.1.4
Transmitter Alarms
The Transmitter Alarms menu displays the active alarms in the transmitter.
NOTE:
If an alarm condition is triggered in a specific transmitter module, when that transmitter is
selected through the HLP 4200 and HLP 4800 interface, the display automatically jumps to the alarm
message within the Transmitter Alarms menu.
3.2 NETWatch
Site
Controller
Harmonic’s NETWatch Site Controller provides a complete element management system,
including a Windows™-based GUI and communications package for monitoring and
controlling a network of multiple SPL 7110-Exx transmitters either remotely or locally. For
information on installing and using this system, consult the
NETWatch Site Controller
Instruction Manual.
3.3
Front Panel LED Indicators
The SPL 7110-Exx front panel includes two LEDs, as shown in
■
The
Status
LED illuminates red if an alarm condition exists within the transmitter, and for a
short period during power up. The
Status
LED illuminates green if no alarm condition
exists and the transmitter is operating normally.
■
The
Select
LED illuminates yellow when the transmitter module is selected via the front
panel controls of the HLP 4200 and HLP 4800.