Technical Specifications
HOA 7100 MAXLink Optical Amplifier Product Manual Rev C (4/05)
A–5
HOA 7114/7117 Alarm Thresholds
HOA 7114/7117 Alarm Troubleshooting
Alarm HiHi SNMP MIB Variable
Default Alarm
HiHi
Threshold
Alarm LoLo SNMP MIB Variable
Default Alarm
LoLo
Threshold
Alarm
Description
16
Laser switch off
alarm
n/a
n/a
n/a
n/a
The laser switch is off.
17
Fiber drawer
optical sensor
alarm
n/a
n/a
n/a
n/a
The fiber drawer is not
closed completely.
18
Optical input
power alarm
n/a
n/a
analogAlarmLOLO.18.heOpAmpInputPower.1.1
-7 dBm
Optical input power is
below threshold.
19
Unit temperature
alarm
analogAlarmHIHI.18.heCommonTemperature.1
75 C
analogAlarmLOLO.18.heCommonTemperature.1
-20 C
Unit temperature
measured at EDFA
module is outside of
threshold range.
20
Laser(s)
temperature alarm
analogAlarmHIHI.18.heOpAmpLaserTemp.1.1
28 C
analogAlarmLOLO.18.heOpAmpLaserTemp.1.1
22 C
Laser(s) temperature is
outside of threshold
range.
21
Laser(s) bias
current alarm
analogAlarmHIHI.18.heOpAmpLaserBiasCurrent.1.1
0, cannot report it
n/a
n/a
At least one pump is
operating at or above
95% of its end of life
value.
22
Optical output
power alarm
n/a
n/a
analogAlarmLOLO.18.heOpAmpOutputPower.1.1
2 dBm below the set
output power
Optical output power is
below threshold.
23
Amplifier Output
Disabled alarm
n/a
n/a
n/a
n/a
The amplifier output is
disabled.
Alarm Parameter
Description
General
Laser System, Optics
Alarm Description
Alarm Troubleshooting
16
Laser switch off alarm
The laser switch is off.
Verify that the Laser Switch located on the rear panel (see Section 3.4) is in the "on" position.
17
Fiber drawer optical
sensor alarm
The fiber drawer is not
closed completely.
Verify that the fiber drawer has been closed completely.
18 Optical input power alarm Optical input power is
below threshold.
Confirm Input Power Level (see Section 2.2).
Go through connector cleaning procedure (see Section 6.1).
Recall factory settings by pressing the RCL function key on the front panel (see Section 2.1.2).
If that does not correct the problem, contact Customer Service (see Section 6.4).
19
Unit temperature alarm
Unit temperature measured
at EDFA module is outside
of threshold range.
Verify that the unit is operating within the proper temperature range (-20 to +60 deg C).
Verify that nothing is obstructing airflow through the openings in the front and back of the unit.
Recall factory settings by pressing the RCL function key on the front panel (see Section 2.1.2).
If that does not correct the problem, contact Customer Service (see Section 6.4).
20
Laser(s) temperature
alarm
Laser(s) temperature is
outside of threshold range.
Verify that the unit is operating within the proper temperature range (-20° to +60° C).
Verify that nothing is obstructing airflow through the openings in the front and back of the unit.
Recall factory settings by pressing the RCL function key on the front panel (see Section 2.1.2).
If none of the above corrects the problem, contact Customer Service (see Section 6.4).
21
Laser(s) bias current
alarm
At least one pump is
operating at or above 95%
of its end of life value.
Check loss of optical power alarms.
Check low input alarm threshold. See Figure 2-6. HOA 7100 Alarms menu on page 2-6.
Recall factory settings by pressing the RCL function key on the front panel (see Section 2.1.2).
If that does not correct the problem, contact Customer Service (see Section 6.4).
22
Optical output power
alarm
Optical output power is
below threshold.
Check Fiber drawer.
Go through connector cleaning procedure (see Section 6.1).
Recall factory settings by pressing the RCL function key on the front panel (see Section 2.1.2).
If that does not correct the problem, contact Customer Service (see Section 6.4)
23 Amplifier Output Disabled
alarm
The amplifier output is
disabled.
Check for other alarms .
Alarm Parameter
Description
Laser System, Optics
General
Summary of Contents for MAXLink HOA 7100 Series
Page 1: ...HOA 7100 MAXLink Optical Amplifier Product Manual Manual Part No 700 0051982 Rev C April 2005...
Page 8: ...Overview 1 4 Copyright 2004 Harmonic Inc...
Page 26: ...Installing the HOA 7100 Optical Amplifier 3 12 Copyright 2004 Harmonic Inc...
Page 34: ...Web Interface 4 8 Copyright 2004 Harmonic Inc...
Page 48: ...Technical Specifications A 6 Copyright 2004 Harmonic Inc...
Page 50: ...Harmonic Inc Offices B 2 Copyright 2004 Harmonic Inc...