Connecting the Alarm Relay
HOA 7100 MAXLink Optical Amplifier Product Manual Rev C (4/05)
3–9
5. Verify that the HOA 7100 optical connector has not been exposed to any
contamination. If you suspect that the connector may have been exposed
to contamination (for example, by a dirty fiber cable connector), follow the
cleaning procedure outlined in Section
6.1.2 Cleaning MAXLink Amplifier
NOTE:
Any contamination of either the fiber cable or HOA 7100 receiver
connector can significantly degrade optical link performance. This
degradation will most likely manifest itself as poor signal-to-noise
(SNR) performance.
6. Note the key characteristics of the mating connectors and align them
accordingly. Gently insert the fiber cable connector into that of the
HOA 7100 until the connector clicks into place.
7. Move the fibers into the groove in the edge of the fiber tray, as shown in
8. Close the fiber tray.
9. Screw the locking screw to secure the fiber tray.
NOTE:
The amplifier ships with the lasers turned off. The Laser Off switch
on the rear panel is in the Off position.
3.9
Connecting the Alarm Relay
The HOA 7100 has a 5-pin alarm relay that provides the amplifier with
redundant switching capability. The alarm relay is located on the rear panel,
as shown in Section
Table 3-1 shows the pin definitions.
When operating normally with no alarm present, Pin 2 and Pin 3 make
electrical contact, while Pin 1 is left open. When an alarm occurs, electrical
contact is made between Pin 1 and Pin 3, while Pin 2 is left open. This remains
until the alarm condition is removed.
Table 3-1:
Alarm Relay Pins
Pin
Label
Function
Pin 1
NO
Normally open
Pin 2
NC
Normally closed
Pin 3
COM
Common
Pin 4
GND
Ground
Pin 5
+24
+24 V source for A/B switch
Summary of Contents for MAXLink HOA 7100 Series
Page 1: ...HOA 7100 MAXLink Optical Amplifier Product Manual Manual Part No 700 0051982 Rev C April 2005...
Page 8: ...Overview 1 4 Copyright 2004 Harmonic Inc...
Page 26: ...Installing the HOA 7100 Optical Amplifier 3 12 Copyright 2004 Harmonic Inc...
Page 34: ...Web Interface 4 8 Copyright 2004 Harmonic Inc...
Page 48: ...Technical Specifications A 6 Copyright 2004 Harmonic Inc...
Page 50: ...Harmonic Inc Offices B 2 Copyright 2004 Harmonic Inc...