Chapter 2 Installing the actuator
- 15 -
RSF-11 B-50-F 100-
□
RSF-B mini series actuator
Frame size: 8,11,14
Reduction ratio of Harmonic Drive
®
gear
Design version
Number of pulses of the encoder
Encoder specifications
Specification
Chapter 2 Installing the actuator
2-1 Receiving Inspection
Check the following when products are received.
●
Inspection procedure
(1) Check the items thoroughly for damage sustained during transportation.
If any item is damaged, immediately contact the dealer.
(2) Confirm the actuator is what you ordered. A label is attached on the right side of the RSF-B mini series
actuator. Check the [TYPE] field on the nameplate to confirm that it is indeed the model you have
ordered. If it is different, immediately contact the dealer it was purchased from.
The model code is interpreted as follows:
For details of model symbols, refer to “1-2 Models” on page 2.
(3) The [INPUT VOL.] line of the driver label indicates the power supply voltage.
The value 24 means 24VDC power supply.
If the power supply voltage written on the label differs from the power supply voltage to be connected
to, immediately contact the dealer it was purchased from.
Only connect the actuator specified on the driver label.
The drivers have been tuned for the actuator specified on the driver label. Wrong
combination of “drivers” and “actuators” may cause low torque problems or over
current that may cause physical injury and fire.
WARNING
Do not connect a supply voltage other than the voltage specified
on the label.
The wrong power supply voltage from those written on the label may damage the
driver resulting physical injury and fire.
WARNING