24
1021387 12/2018
V02
Output Bearing and Housing Tolerances
In the case of the SHG-2UH Unit the load is connected to the output bearing by means of a flange. Depending on the manner
of fastening, either the flange which is connected to the outer ring, or the flange which is connected to the internal ring of
the output bearing, can be used as output element (see illustration 24.1 and illustration 24.2). The tolerance values indicated
in table 24.3 are the sum of bearing and flange tolerances.
Illustration 24.2
Illustration 24.1
Table 24.3
Am Gehäuse befestigt
Am Gehäuse befestigt
Abtrieb
Abtrieb
Mounted to housing
Mounted to housing
Output
Output
Symbol
[Unit]
SHG-14
SHG-17
SHG-20
SHG-25
SHG-32
SHG-40
SHG-45
SHG-50
SHG-58
SHG- 65
A [mm]
0.033
0.038
0.040
0.046
0.054
0.057
0.057
0.063
0.063
0.67
B [mm]
0.035
0.035
0.039
0.041
0.047
0.050
0.053
0.060
0.063
0.63
C [mm]
0.064
0.071
0.079
0.085
0.104
0.111
0.118
0.121
0.121
0.131
D [mm]
0.053
0.053
0.059
0.061
0.072
0.075
0.078
0.085
0.088
0.089
E [mm]
0.040
0.045
0.051
0.057
0.065
0.071
0.072
0.076
0.076
0.082
F [mm]
0.038
0.038
0.047
0.049
0.054
0.060
0.065
0.067
0.070
0.072
G [mm]
0.037
0.039
0.046
0.047
0.059
0.063
0.070
0.070
0.070
0.076
H [mm]
0.031
0.031
0.038
0.038
0.045
0.048
0.050
0.050
0.050
0.054
I [mm]
0.064
0.071
0.079
0.085
0.104
0.111
0.118
0.121
0.121
0.131
K [mm]
0.053
0.053
0.059
0.061
0.072
0.075
0.078
0.085
0.088
0.089