Chapter 10 Design and Precautions on assembly
19
10-3 Mounting in system
When mounting the CSF-3 series in a system, check flatness of the mounting surface and burrs in the
tap part. Then clamp the mounting flange (Part A in the diagram) by bolting.
Bolt tightening torque for mounting flange
Model No.
3
Number of bolts
4
Bolt size
M1.6
Mounting PCD
mm 15
Nm 0.26
Tightening torque
kgf m
0.03
Minimum length for
fastener fit
mm 1.9
Nm 3.0
Transfer torque
kgf m
0.3
Recommended bolts: Hexagon socket head cap screws (JIS B 1176); strength, 12.9 or better (JIS B
1051)
Mounting flange
Part A