TROUBLESHOOTING
PINNACLE STAIR LIFT: SECTION 6
MINOR FAULTS
Single long beep. Will reset once the fault is cleared.
•
Seat swiveled out of position
•
Edge safety detected
(SL600FR only)
•
Footrest
•
Current overload condition
•
A low battery voltage condition
PULSING BEEP
An intermittent beep for 30-seconds indicates that
the lift has been stopped off the charge station. This
repeats every 5 minutes until the lift is returned
to the charge station. It is recommended that the
lift be immediately moved to a charge strip station
located at either end of the rail.
MANUAL OVERRIDE
OPERATION
If your lift fails to operate and the operator is unable
to exit the lift on the stairway, another person may
use the optional manual override tool to lower or
raise the lift to a landing. However, please follow the
instructions on the bottom safety flap of the lift and
turn the on/off switch to “Off”. Insert the manual
override tool into the hole in the lower safety flap
until it engages the motor shaft, then turn in the
direction desired.
Do not operate the lift with the manual lowering
tool engaged.
WARNING
!
NOTE: A 7mm nut driver or 7mm socket can be used if a
manual lowering tool is not available.