background image

3-90-08422R34_08/13

2

PP38+ Pellet Stove

"PREVENT

 HOUSE FIRES"

Install and Use Only in 

Accordance With Manufacturer's Installation and Operation Instructions.

Contact Local Building or Fire Officials 

About Restrictions and Installation Inspection in 

Your 

Area.

W

ARNING : 

THE STRUCTURAL

 INTEGRITY

 OF 

THE MANUF

ACTURED HOME FLOOR, W

ALL,

AND CEILING/ROOF MUST

 BE MAINT

AINED. DO NOT

 INST

ALL

 IN SLEEPING ROOM.

An outside combustion air inlet must be provided. Refer to Manu

facturer

’s instructions and local

codes regarding the requirements for passing the exhaust ventin

g system through a combustible

wall or ceiling.

Inspect and Clean Exhaust V

enting System Frequently

.

Use a 3" or 4" diameter type "L" or "PL" venting system.

Do Not Connect 

This Unit to a Chimney Flue Serving 

Another 

Appliance.

FOR USE WITH WOOD PELLET

 FUEL

 OR UP

 T

O 50% CORN / PELLET

 MIXTURE ONL

Y.

The Use of Other Fuels May Create an Unsafe Condition.

Input Rating Max: 5.5 lb. fuel/hr

.

U.S. Electrical Rating: 1

15 V

AC, 60 Hz, Start 4.2 

AMPS, Run 2.8 

AMPS

Route Power Cord 

Away From Unit.

DANGER:

 Risk of Electrical Shock. Disconnect Power Before Servicing Un

it.

For Further Instruction, Refer 

To Owner's Manual.

Replace glass only with 5mm ceramic available from your dealer

.

Keep V

iewing and 

Ash Removal Doors 

Tightly Closed During Operation.

DO NOT

 REMOVE 

THIS LABEL

 / NE P

AS ENLEVER CETTE ÉTIQUETTE

MINIMUM CLEARANCES 

TO COMBUSTIBLES/

DIST

ANCES DE SECURITE P

AR RAPPOR

T AUX

MA

TERIAUX COMBUSTIBLES:

Back W

all / Entre Mur 

Arrière  

2”/ 51mm 

2”/ 51mm

Side W

all / Entre Paroi Latér 

16”/ 406mm 

10”/ 254mm

CORNER INST

ALLA

TION / EN 

ANGLE

W

alls to 

Appliance  

9”/228mm 

9”/228mm

Entre Murs et appareil Flue Connector/Raccord à la cheminée     3” /76mm

FLOOR PROTECTION / Protection Du Plancher  

     

USA

 

Canada

Sides*/

Côtés   (A)     6” 

200mm

Back**/

Arrière (B)     6” 

200mm

Front*/

Avant   (C)     6” 

450mm

**Measured from pedestal base in the US ONL

Y

**Mesuré à partir de la base du socle aux États-Unis uniquement *Measured from Glass Opening *Mesurer à partir de la surface de la porte en verre

Floor Protection Must Be a Non-Combustible Material. Must 

Also 

be 

Place 

Under 

Any 

Horizontal 

Flue 

Connector

Extending 2” or 51mm Beyond the Pipe Measurement. Pour 

protéger 

le 

plancher

, il 

faut 

sous 

le 

pêole 

un 

matériau. 

Qui 

doit 

aussi 

être 

placé 

sous 

les 

parties 

horizontales 

du 

tuyau 

de 

raccord 

à 

la 

cheminée 

et 

s’étendre 

à 

51mm 

po. 

au-delà 

de 

la mesure du tuyau.

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

"PREVENTION DES INCENDIES" Respecter scrupuleusement les instructions du constructeur pour l'installation et les consignes de fonctionnement. Respecter les règles de sécuritè en vigueur 

dans votre région.

AVER

TISSEMENT

 POUR MOBILE HOMES:

 Ne pas installer dans une chambre. ll est imperatif

de prévoir une prise d'alr extérieur

. L'intégrité structurale du plancher

, du plafond et des murs doit étre

strictement préservée. Se reporter aux instructions du fabrican

t et aux réglementations spécifiques

locales concernant les précautions requises lors de la traversé

e d'un mur ou d'un plafond.

Contróler et nettoyer fréquemment tout le systeme d'evacuation 

des fumées conformément aux

recommandations du constructeur

. Utiliser des tuyaux <<Spécial granulés>> de Ø76 mm ou

102 mm. Ne pas raccorder ce poéle à un conduit de cheminée déjà

 utilisé pour un autre appareil.

FONCTIONNE EXCLUSIVEMENT

 AVEC DES GRANULES DE BOIS

.

Appareil de chauf

fage à granulé type. Consommation maximum: 2.5 kg/h.

US coupure: 1

15 V

AC, 60 Hz, 4.2 amps Démarrer

, Exécuter 2.8 

AMPS

fonctionnement normal 1.1A. 

Tenir le cordon d'alimentation à l'écart du poèle.

DANGER:

 Risque d'électrocution. Débrancher l'appareil avant toute inte

rvention.

Ne remplacer la vitre qu'avec une vitre céramique 5mm de méme q

ualité disponible

auprès de votre revendeur

.

Pour une information plus compléte, se reporter à la notice d'u

tilisation. 

Tenir la porte

hermétiquement close durant fonctionnement. Ne faites pas obstacle l’espace sous le réchauf

feur

. T

oujours fournir un approvisionnement suffisant en air frais 

jusqu’au lieu d’installation 

Appliance

P.N. 3-90-04300

WITHOUT

SIDE SHIELDS

WITH

SIDE SHIELDS

Sans Écrans

Latéraux

Avec Écrans

Latéraux

US ENVIRONMENT

AL

 PROTECTION 

AGENCY

This model is exempt from EP

A certification under 40 CFR 60.531

by definition [W

ood Heater (A) "Air-to-Fuel Ratio"]

Agence 

Américaine pour la Protection de l’Environnement

Ce modéle est dispensé par EP

A certification d’aprés 40 CFR 60.531

par dèfinition [Appareil á bois (A) << Ratio air/combustible>>]

Date of Manufacture / Date de fabrication:

Fabriqué par: Hearth and Home 

Technologies 352 Mountain House Road, Halifax P

A 17032

2013   2014   2015   JAN   FEB   MAR   

APR   MA

Y   JUN   JUL

   

AUG   SEP

   OCT   NOV   DEC

H

ar

m

an

 P

P

38+

/P

43 

P

el

le

t S

to

ve

B

la

ck

 B

ac

kg

ro

un

w

ith

 b

ar

m

et

al

 fo

r p

rin

t-a

dh

es

iv

ba

ck

ed

, m

et

al

 p

la

te

.

BARCODE LABEL

008

Serial No. N

o

 de série:

Report #/ Raport #135-S-21-6.2 (PP38+) Report #/ Raport #135-S-23-4, 135-S-23b-6.2 (P43) Tested to / 

Testé à:

ASTM E1509-04, ULC/ORD-C1482-M1990,  ULC-S627-00

Room Heater Pellet Fuel Burning 

Type. 

Also for use in Mobile Homes.

Appareil de chauf

fage à granulés de bois Utilisable dans des mobile homes. 

This pellet burning appliance has been tested and listed for us

e in Manufactured 

Homes in accordance with OAR 814-23-900 through 814-23-909

M

O

D

E

/ M

O

D

È

LE

:  

   

 "P

P

38+

 / 

   

   

P

43"

2"(51mm)

10" (254mm) with side shields 16" (406mm) w/out side shields

A

A

C

B

USA

CANADA

F

loor

 

protect

or

PROTECTiON DE SOL FLOOR PROTECTiON

9"(228mm) 

9"(228mm)

3"   m i n

76

m

m

 m

in

3"

 m

in

7 6 m m   m i n

Rev D

10-3/4"

4-3/8"

The label shown here is for referrence only

. For specific 

in

fo

rm

a t

io

n  o

n  c

lea

ra

n c

es

 a

n d

 tes

tin

g ,

 c

o n

s u

lt t

h e a

c t

u a

la

b el

 o

n  t

h e r

ea

r o

f t

h e P38 f

u el

 h

o p

p er

.

Summary of Contents for PP38 plus

Page 1: ...ATiON EST DiSPONiBLE EN FRANCAiS CH EZ VOTRE CONCESSiONNAiRE DE H ARMAN H OME H EATiNG Mo d el s PP38 Freestanding Pellet Stove NOTICE SAVE THESE INSTRUCTIONS H o t g l a s s w i l l c a u s e b u r n s Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as stove Alertchildrenandadultstohazardsofhightemperatures H i...

Page 2: ... structurale du plancher du plafond et des murs doit étre strictement préservée Se reporter aux instructions du fabricant et aux réglementations spécifiques locales concernant les précautions requises lors de la traversée d un mur ou d un plafond Contróler et nettoyer fréquemment tout le systeme d evacuation des fumées conformément aux recommandations du constructeur Utiliser des tuyaux Spécial gr...

Page 3: ... raccord à la cheminée et s étendre à 51mm o 2 po au delà de la mesure du tuyau Made in U S A of US and imported parts Fabriqué aux États Unis d Amérique par des pièces d origine américaine et pièces importées PREVENTION DES INCENDIES Respecter scrupuleusement les instructions du constructeur pour l installation et les consignes de fonctionnement Respecter les règles de sécuritè en vigueur dans vo...

Page 4: ... UALiFiED SERViCE PERSON PERiODiC CLEANiNG iS REQ UiRED TH ROUGH OUT TH E H EATiNG SEASON AND AT TH E END OF EACH W iNTER FOR TH E STOVE TO W ORK EFFiCiENTLY REFER TO TH E MAiNTENANCE SECTiON OF TH iS MANUAL W ARNiNG MOBiLE MANUFACTURED H OME STANDARDS DO NOT ALLOW iNSTALLATiON iN ROOMS DESiGNATED FOR SLEEPiNG CAUTiON ALW AYS BE SURE TH ERE iS NO UNBURNED FUEL iN TH E ASH PAN PRiOR TO LiGH TiNG A ...

Page 5: ...long with all local codes regarding installation of this appliance Do NOT use makeshift compromises when installing this appliance serious consequences may result With any hearth appliance installation of smoke detectors is recommended on every level of the home Po s s i b l e c a u s es o f s m o k e d et ec t o r a c t i va t i o n Paint curing process Open a window near the appliance for the fi...

Page 6: ... 05 lower than the first reading check for possible restrictions or the need for outside air see page 10 For more information on the draft test procedure refer to Page 19 Mo b i l e H o m e in s t a l l a t i o n When installing this unit in a mobile home several requirements must be followed 1 The unit must be bolted to the floor This can be done with 1 4 lag screws through the 2 holes in the bas...

Page 7: ...measured from the horizontal center line of the regulator I The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air supply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48 K The clearance to a mechanical air supply inlet must be a minimum of 10 feet w i t h o u t s i d e a i r i n s t a l l e...

Page 8: ...or this reason and the fact that the unit operates with a positive vent pressure w e s p ec i f y t h a t t h e j o i n t s a l s o b e s ea l ed w i t h h i g h t em p RTV s i l i c o n e Aluminum tape can also be used for any joint that is 1ft or more from the outlet of the stove NOTE Si m p s o n Du r a Ven t Pel l et Ven t Pr o H a r m a n Ad a p t er Pa r t 3PVP ADH B a n d Pel l et Ven t Pr ...

Page 9: ...size must be increased to 3 Inlet cover part number 1 10 08542 should be used to keep birds rodents etc out of the pipe You may choose to use the optional Direct Vent Wall Passthrough Kit part 1 00 677077 which incorporates the venting passthrough and outside air inlet into one component Ven t i n g Outside air flex pipe goes here Inlet Cover part 1 10 08542 Direct Vent Wall Passthrough Kit part 1...

Page 10: ...od provides excellent venting for normal operation and allows the stove to be installed closest to the wall Two inches from the wall is safe however four inches allows better access to remove the rear panel The vertical portion of the vent should be three to five feet high This vertical section will help provide natural draft in the event of a power failure No t e Do n o t p l a c e j o i n t s w ...

Page 11: ...ey This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questionable you may want to install a liner as in method 6 In some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney The chimney should be inspected and cleaned before installing ...

Page 12: ... Be sure to use approved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 7 in s t a l l i n g i n t o a n ex i s t i n g c h i m n ey This method provides excellent venting for normal operation This method also provides natural draft in the event of a power fail...

Page 13: ...nd support See Page 7 for corner installation clearances Minimum flue vent configuration It is required that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure Min above ground level 12 Storm collar Flashing 3 min 3 min 12 min 3 min Ven t i n g Fi g 15 3 min No insulation or other combustible materials are allowed w...

Page 14: ...u to adjust the stove temperature while in Stove Temp Mode using the inner scale marked from 1 to 7 Mode Selector Allows you to choose between Room Temp Mode Stove Temp Mode or OFF Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode Power Light Indicates power to the control Indicates power to the feed motor Indicates power to the combusti...

Page 15: ...s required the stove will gradually slow down and hold at the minimum burn rate When the house cools down the stove will automatically bring the room temperature to the precise temperature you desire In the Room Temperature Mode the distribution blower speed can be increased or decreased by adjusting the Room Temp Off Stove Temp dial between L and H As output of the stove increases the speed of th...

Page 16: ...bustion blower and smoke will escape through window and door gaskets Feed Ad j u s t er K n o b For most premium grade pellet fuels the Feed Adjuster Knob should be set at 4 If higher ash fuels are used the setting should be increased to 5 or 6 Also higher settings are required if you would like to get the maximum heat output from the stove At the maximum burn rate with the temperature dial on 7 9...

Page 17: ...pan can hold the ashes from approximately 1 ton of premium fuel This means the ashes will only need to be emptied a few times a year 7 Setting the feed adjuster for maximum burn With the unit burning in AUTO turn to Stove Mode and put the fan on H Set the Temperature Dial to 7 Allow the unit to burn for about 30 minutes and check ash on front of burn pot Fig 18 If the ash line is larger than 1 tur...

Page 18: ...conds to pass for the combustion motor to slow before checking the low draft 6 If the low draft is between 25 and 35 record the reading _____ in W C If the reading is lower check for resistance in the venting configuration Too many elbows or excessive horizontal runs will add resistance Also be sure the doors and hopper lid are properly secured As long as the draft reading drops when the combustio...

Page 19: ...be cleaned Clean the glass with a soft cloth and mild glass cleaner Do not clean the glass when hot and avoid the use of abrasive cleaners Glass replacement Carefully remove all remaining glass and gasket materials prior to replacing the glass Lay the door face down on a flat surface Remove the glass retainers and screws Apply the gasket material to the face of the new glass Lay the glass into the...

Page 20: ...l y d i s p er s ed t h ey s h o u l d b e r et a i n ed i n t h e c l o s ed c o n t a i n er u n t i l a l l c i n d er s h a ve b een t h o r o u g h l y c o o l ed Ot h er w a s t e s h a l l n o t b e p l a c ed i n t h i s c o n t a i n er Cl ea n i n g It is recommended that the stove is cold and shut down when removing the ash pan 1 Lift the latch handle to open the ash door and remove the...

Page 21: ...E PELLETS iF SUCK ED iNTO TH E VACUUM W iLL LiGH T TH E VACUUM ON FiRE AND MAY ULTiMATELY CAUSE A H OUSE FiRE 9 Use a brush to clean the flue being careful not to damage the ESP probe see Fig 30 The flue goes straight through into the vent pipe Fig 27 therefore the vent pipe can also be cleaned to some extent through the flue outlet 10 Reinstall the blower cover and close the latch 11 Slide the as...

Page 22: ...ront angle of the burn pot Fig 34 3 Lift off the clean out cover Fig 35 to open the bottom clean out chamber Fig 36 4 Clean ash buildup from inside the chamber while cover is off Use the scraper to tap on the top front edge of the burn pot This will help knock pieces of ash loosened by the scraping process down through the holes 5 Be sure the cover is in place on the screws and hand tighten the wi...

Page 23: ...tive pressure draft in the firebox through a port on the rear of the feeder Poor draft will result in an interruption of power to the feeder motor Poor draft can be caused by blockage in the exhaust excessive build up on the combustion blower fan blades a failed combustion blower or a door or other opening to the firebox not sealed properly The circuit board is monitoring the position of this swit...

Page 24: ...he above 5 6 s t a t u s b l i n k A 6 blink control board status indication is caused by poor or incomplete combustion The circuit board has the ability to track the combustion through feed settings and ESP temperatures When the control board has calculated poor or incomplete combustion it will shut down the unit as a safety feature Poor or incomplete combustion is a contributor of creosote which...

Page 25: ...28 5 8 W ei g h t 212 l b s Bl o w er 135 c f m Feed Ra t e a p p r o x i m a t e 7 5l b t o 5 5 l b s p er h r H o p p er Ca p a c i t y 50 l b s Fu el W o o d Pel l et s Fl u e Si ze 3 i n c h Ou t s i d e Ai r Si ze 2 3 8 i D i n c h Fu s e Ra t i n g 6 a m p 13 3 4 5 1 4 22 ...

Page 26: ...rim kit is necessary to hold the slate in place on the stove There are 4 decorative slate choices See dealer for samples The Brushed Stainless deer cutout pictured below is another option available This cutout reveals the color of the stove through the cut out shapes 5 938 11 938 Frame Tile Slate On the rear of the stove hopper there is a hole to fasten the hopper extension into place On some unit...

Page 27: ...et temperature knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate After the stove has burned for 10 minutes and the entire fuel bed is burning the feed adjuster may be set to a higher output level if desired Maximum feed has been reached when the fire ...

Page 28: ... moisture content takes energy to dry and tends to cool the appliance thus robbing heat from your home Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system Size Pellets are either 1 4 inch or 5 16 inch 6 8mm in diameter Length should be no more than 1 1 2 inches 38mm Pellet length can vary from lot to lot from the same manufacturer Performance Higher a...

Page 29: ...ONNECTIONS 1 4 2 3 6 5 9 8 7 WHITE WHITE WHITE WHITE BLUE EMPTY EMPTY PLUGGED BROWN 11 BLACK PART NO 3 90 773869 WHITE 11 PIN PLUG 10 RED GREEN BONDED TO STOVE BODY GREEN WIRE IS GROUND 1 8 3 R U B B E R C O R D P O W E R C O R D ESP HARMAN P38 PELLET STOVE WIRING DIAGRAM BOARD CONTROL BROWN WHITE RED BLUE WHITE WHITE GREEN MALE FEMALE CONNECTIONS ESP BLACK ROOM SENSOR PORTS WHITE ESP PROBE 3 1 9 ...

Page 30: ...n the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period fo...

Page 31: ...ty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plat...

Page 32: ...Pre SN 008080066 Refer to following page 3 Feeder Assembly Post SN 008080066 Refer to following page 4 Flue Tail Pipe 3 00 247237 Y 5 Auger Motor Cover 2 00 773852P Y 6 Auger Motor Shield 2 00 773815P Y 7 Differential Switch 3 20 6866 Y Additional service parts on following page 8 13 1 7 0 08500 1 Bl a c k En d i n g Ma n u f a c t u r i n g Da t e Ma y 2006 1 9 0 08500 2 Ch a r c o a l En d i n g...

Page 33: ... 10 7738108A Y 15 Ash Door Assembly Pre 008080066 1 10 773871 Post 008080066 1 10 7738106A 16 Bolt on Hinge Weldment 2 00 06952B 17 Cast Door Frame 4 00 06800P Cast Door w Glass 1 10 06800A 18 Glass Panel 3 40 950133125 Y Glass Clip w hardware Pkg of 4 Pre 00880001 1 00 773862 Post 00880001 1 00 249140 Y 19 Door Handle Assembly Contains Paw Bolt Wooden Handle Washers and Screws Pre 10327 1 00 0870...

Page 34: ... t i o n COMMENTS PART NUMBER 2 Feeder Assembly 1 10 09525 2 1 Air Intake Damper Assembly 1 10 06466W 2 2 Air Intake Weldment 1 10 773843 2 3 Feeder Weldment 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Assembly 1 10 773890 Y 2 6 Feed Cover and Gasket 2 Sets 1 00 677152 Y 2 7 Auger Assembly 3 50 00465 Y 2 8 Cam Bearing 3 31 3014 Y 2 9 Bearing Flange w Hardware 1 00 04035 Y 2 ...

Page 35: ...1 10 06810A 3 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 3 6 UL Feeder Air Intake 1 10 72222 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132 Y 3 9 UL Feeder Pusher Arm 1 10 677187W Y 3 10 Fines Deflector No longer available 2 00 677138 10 3 11 Gasket UL Feeder Cover 1 00 677122 Y 3 12 Slide Plate Assembly 1 10 677121A Y 3 13 UL Feeder Auger Asse...

Page 36: ...4 Rope Black W PSA Glass 15 Ft 1 00 2312 Y Gasket 3 8 Rope White LD Ash Door or Load Door 30 Ft 1 00 00888 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y Gasket Hopper Lid 1 00 00248 Y Hopper Lid W HInge 1 10 08518 Y Labels Caution Danger 10 ea 1 00 200408541 Label Caution 3 90 08416 Latch Swell Hopper 1 00 199110 Y Spacer Pkg of 10 3 31 901311 10 Hopper Muffler and Fittings 1 set 1 00 18186618 ...

Page 37: ...37 P P 38 P e l l e t S t o ve 3 90 08422R34_08 13 Ser vi c e Ma i n t en a n c e Lo g Date Of Service Performed By Description Of Service ...

Page 38: ...sts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA Proudly Printed On 100 Recycled Paper ...

Reviews: