13
P P 38+ P e l l e t S t o ve
3-90-08422R34_08/13
# 8 in s t a l l i n g t h r o u g h t h e c ei l i n g
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass through.
No t e: Do n o t p l a c e j o i n t s w i t h i n w a l l p a s s - t h r o u g h s .
Fi g . 14
PL vent manufacturer's
firestop spacer and support
(See Page 7 for
corner installation
clearances)
Minimum flue vent configuration
It is required that outside air
be installed with this venting
configuration to reduce smoke and
creosote smell in the room in the
event of power failure.
Min. above ground level
12"
Storm collar
Flashing
3" min.
3" min.
12" min.
3" min.
Ven t i n g
Fi g . 15
3" min.
No insulation or
other combustible
materials are allowed
within 3" of the pellet
vent pipe. Unless
specified by the pipe
manufacturer
Fi g . 16
12"
min. wall to outlet
36"
min. clear
anc
e to an
y
combustable ma
terial